DATA

MUZ-JP09WA MUZ-JP12WA
7-1. PERFORMANCE DATA
1) COOLING CAPACITY
Indoor air
Model
IWB (˚F)
71
MUZ-JP09WA
67
63
71
MUZ-JP12WA
67
63
NOTE: 1. IWB : Intake air wet-bulb temperature
SHC : Sensible Heat Capacity (x10
2. SHC is based on 80˚F of indoor Intake air DB temperature.
2) COOLING CAPACITY CORRECTIONS
Refrigerant piping length (one way: ft.)
Model
25 (std.)
MUZ-JP09WA
MUZ-JP12WA
3) HEATING CAPACITY CORRECTIONS
Refrigerant piping length (one way: ft.)
Model
25 (std.)
MUZ-JP09WA
MUZ-JP12WA
4) HEATING CAPACITY
Indoor air
Model
IDB (˚F)
75
MUZ-JP09WA
70
65
75
MUZ-JP12WA
70
65
NOTE: 1. IDB : Intake air dry-bulb temperature
TC : Total Capacity (x10
2. Above data is for heating operation without any frost.
How to operate with fixed operational frequency of the compressor
1. Press the EMERGENCY OPERATION switch on the front of the indoor unit, and select either EMERGENCY COOL
mode or EMERGENCY HEAT mode before starting to operate the air conditioner.
2. The compressor starts with operational frequency.
3. The fan speed of the indoor unit is High.
4. This operation continues for 30 minutes.
5. In order to release this operation, press the EMERGENCY OPERATION switch or press any button on the remote con-
troller.
OBH821A
75
TC
SHC TPC
11.0
7.6
0.67 10.3
10.4
8.6
0.63
9.8
9.4
0.60
14.7
9.4
1.08 13.7
13.9 10.7 1.02 13.0 10.0 1.12 12.0
13.1 11.8 0.97 12.1 10.9 1.07 11.3 10.2 1.16 10.3
3
Btu/h) TPC : Total Power Consumption (kW)
40
1.0
0.988
40
1.0
0.997
5
15
TC
TPC
TC
4.8
0.53
6.3
5.2
0.51
6.7
5.5
0.49
6.9
5.4
0.58
7.1
5.8
0.56
7.5
6.1
0.53
7.7
3
Btu/h)
Outdoor intake air DB temperature (˚F)
85
TC
SHC TPC
TC
SHC TPC
7.1
0.73
9.7
9.7
8.0
0.69
9.0
9.1
8.7
0.66
8.5
8.7
1.18 12.9
TC
: Total Capacity (x10
65
100
0.967
65
100
0.993
Outdoor intake air WB temperature (˚F)
25
TPC
TC
TPC
TC
0.67
7.9
0.79
9.4
0.65
8.2
0.77
9.6
0.62
8.6
0.74
10.0
0.74
8.8
0.87
10.6
0.71
9.2
0.85
10.8
0.68
9.6
0.82
11.2
TPC : Total Power Consumption (kW)
11
95
105
TC
SHC TPC
6.6
0.79
9.0
6.2
0.83
7.4
0.75
8.4
6.9
0.80
8.1
0.72
7.7
7.3
0.77
8.2
1.27 12.0
7.6
1.34 11.0
9.2
1.21 11.2
8.6
1.28 10.3
9.3
1.23
3
Btu/h)
35
43
TPC
TC
TPC
TC
0.88
10.6
0.92
11.0
0.86
10.9
0.90
11.2
0.83
11.2
0.88
11.6
0.97
11.9
1.01
12.3
0.94
12.2
0.99
12.6
0.92
12.6
0.97
12.9
115
TC
SHC TPC
8.3
5.7
0.86
7.7
6.3
0.83
7.0
6.7
0.80
7.0
1.39
7.9
1.34
9.4
8.5
1.28
45
55
TPC
TC
TPC
0.94
12.4
0.97
0.92
12.7
0.95
0.89
13.0
0.94
1.03
13.9
1.07
1.01
14.2
1.05
0.98
14.5
1.03