LN-10/DH-10 Wire Feeder Compatibility Note:
The LN-10 and DH-10 feeders can be used to pulse weld and
in the power mode with the panel. The displays on the LN-10
& DH-10 do not show the wire feed speed or power.
9. SERIAL PORT FOR SOFTWARE UPDATES
10. HOT START and ARC CONTROL features have differ-
ent functions depending on the welding Mode that is active.
Each feature is described under the welding mode heading.
(See Item 8 or 8A for specified Mode Operations) (See
Figure B.1 or B.2)
(
LOWER CASE PANEL
See Figure B.1)
The output studs, Meter Polarity switch and remote connector
are located on the lower case front.
11. Both Output terminals are "STUD" connectors.
12. The METER POLARITY switch is located above the out-
put connectors. The switch provides a work connection
for wire feeder voltmeters. Place the switch in the position
of the electrode polarity indicated by the decal. The
switch does not change the welding polarity.
13. 6-pin MS-style connector for remote control.
14. 14-PIN MS-style connector for wire and remote control.

15. AUXILIARY POWER

• 115VAC, 42VAC and 24VAC power is available from the
14-pin MS-style connector.
• 42 VAC supply is rated at 10 amps.
• 24 VAC supply is rated at 10 amps.
• 115VAC outlet rated at 15* amps.
* Earlier models used a 10 amp circuit breaker.

REMOTE CONTROL SELECTION

The INVERTEC® V450-PRO has auto sensing of remote out-
put controls. If after connecting or removing a remote, the
INVERTEC® V450-PRO did not configure the way you would
like the local or remote control settings can be changed by
pushing the OUTPUT CONTROL or WELD TERMINAL but-
ton. (A user cannot select between the 6 and 14 pin MS-style
connectors.)
CV modes
• The remote will default to the 14-pin MS-style connector if a
remote is connected. If no remote is connected to the 14-
pin MS-style connector then the remote will default to the 6-
pin MS-style connector if a remote is connected to it.
• In all of the CV modes, the WELD TERMINAL control will
default to REMOTE.
All manuals and user guides at all-guides.com
OPERATION
INVERTEC® V450-PRO
TIG mode
• The remote will default to the 6-pin MS-style if a
remote control is connected to the 6-pin MS-style
and to the 14-pin MS-style connector. If a remote is
not connected to the 6-pin MS-style connector then
the remote will default to the 14-pin MS-style con-
nector if a remote is connected.
• If a remote control is connected to any of the MS-
style connectors the WELD TERMINAL control will
default to REMOTE. If there are not any remote
control devices attached the WELD TERMINAL con-
trol will default to ON.
CC-Stick modes
• The remote will default to only the 6-pin MS-style
connector if a remote is connected to it.
• The WELD TERMINAL control will default to ON
with or without a remote connected.
Types of Remote OUTPUT CONTROL
• The INVERTEC® V450-PRO's Output Control can
be controlled by either a potentiometer connected
between 77 & 75 with the wiper connected to 76 or
a 0V to 10V DC supply connected between 76 & 75.
(76 needs to be positive)
• 14-Pin Ms-style connector lead 75 is pin G, lead 76
is pin F and lead 77 is pin E.
• 6-Pin Ms-style connector lead 75 is pin C, lead 76 is
pin B and lead 77 is pin A.
Potentiometer Control
• The total resistance should be between 2000 ohms
(2K) and 10,000 ohms (10K)
• The machine output will be at minimum when lead
76 (wiper) is at the end of the potentiometer that is
connected to 75. The machine's output will increase
as the wiper of the potentiometer is moved to the
end that is connected to 77. (Note: In TIG mode,
moving the lead 76 (wiper) to lead 77 would pro-
duce the current that has been set by the
INVERTEC® V450-PRO's front panel Output
Control.)
• Remotes of this type offered by Lincoln Electric are
the K857, K812 and K870.
Voltage Control
• The supply should be an isolated supply. (Not refer-
enced to earth ground, any auxiliary power from the
INVERTEC® V450-PRO or the welding output) The
supply should be capable of supplying at least
20mA.
• 0 volts supplied to 76 will set the INVERTEC®
V450-PRO to minimum output for the mode that has
been selected while 10 volts supplied to 76 will set
the INVERTEC® V450-PRO to the maximum output
for the mode. (Note: In TIG mode, 10 volts supplied
to lead 76 would produce the current that has been
set by the INVERTEC® V450-PRO's front panel
B-8