Phase Switch - Rockford Fosgate Power Elite T20001bd Installation And Operation Manual

Power series mono amplifiers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
O
PERATION

PHASE SWITCH

Used when bridging two bd amplifiers together using a bd Sync cable to phase one amplifier 180° from
the other when driving a common load.
The bd Sync cable must be used to allow the two independent frequency carrier generators in each unit
to be synchronized.
bd Sync Wiring
NOTE:Only the controls on the first (Master) amplifier
need to be set.The gain on the subsequent (Slave)
amplifiers can be used for fine-tuning.
12
Set to
MASTER
Minimum
8 AWG Cable
Maximum
15"(38.1cm) Long
Set to
SLAVE
Set to
SLAVE
Minimum
8 AWG Cable
Maximum
15"(38.1cm) Long
To Amplifiers 5 and 6
and so on
Amplifier 1
bd Sync
Cable
Amplifier 2
Amplifier 3
bd Sync
Cable
Amplifier 4