Download Print this page

Advertisement

Quick Links

 
 
 
© Adam Equipment Company 2019
AE 504 
 
Software rev: V 1.00 & above
Adam Equipment 
 
 
 
 
 
 
 
 

Advertisement

loading
Need help?

Need help?

Do you have a question about the AE 504 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Adam Equipment AE 504

  • Page 1 Adam Equipment      AE 504    Software rev: V 1.00 & above                   © Adam Equipment Company 2019...
  • Page 2     Easy Reference:        Model name of the indicator/scale:   Serial number of the unit:   Software revision number  (Displayed when power is first turned on): Date of Purchase:    Name of the supplier and place:                     © Adam Equipment Company 2019...
  • Page 3 BATTERY AND BACKLIGHT OPERATION .................. 32 11.1 BATTERY ............................ 32 11.2 CHARGING..........................33 11.3 BACKLIGHT FOR LCD ........................ 33 12.0 ERROR CODES ..........................34 13.0 REPLACEMENT PARTS AND ACCESSORIES ................35 14.0 SERVICE INFORMATION ....................... 36 WARRANTY INFORMATION ......................... 37 © Adam Equipment Company 2019...
  • Page 4   INTRODUCTION  The AE 504 series provides a versatile check counting and weighing application perfect for general warehouse and production.  The indicators can be set to verify counts up to 60000 divisions  All indicators are supplied with a RS-232 bi-directional interface and real time clock (RTC).
  • Page 5 Interface RS-232 bi-directional interface English, German, French, Spanish selectable text Date/Time Real Time Clock (RTC), To print date and time information (Dates in Year/month/day, Day/month/year or Month/day/year formats- Battery backed)   © Adam Equipment Company 2019...
  • Page 6 Avoid air movement such as from fans or opening doors. Do not place near open windows or air- conditioning vents.  Keep the indicator clean. Do not stack material on the indicator when they are not in use.     © Adam Equipment Company 2019...
  • Page 7 This indicator must be connected to a load cell platform and calibrated as necessary to match the platform and user requirements. The AE 504 has a connector configured for 4-6 wire load cells. Connect the load cells/platform to the indicator as shown below. The cable length should be as short as possible, using a large size wire to minimise errors due to resistance in the leads.
  • Page 8 Used to access any stored PLU weight values [CE/ Used to clear numeric totals on the display. BACKLIGHT] Secondary function: Allows the backlight to be configured to ON/ OFF/ AUTO [U 1-6] Fetch a stored PLU value directly © Adam Equipment Company 2019...
  • Page 9 Tare: Used as tare key in pricing mode Lo-bat: When battery power lower than 5.6V, it will show. Kg / Lb / g / oz : Symbols shown for the units Net: Net weight- The scale has been tared © Adam Equipment Company 2019...
  • Page 10 In the unit weight Window, it will show “weight” or “count”, press [M+] key to change the alarm settings. OPERATION NOTE: AE 504 only SETTING THE WEIGHING UNIT, lb or kg The indicator will turn on displaying the last weighing unit selected, either kilograms or pounds.
  • Page 11 Take away the container and weights, the weight windows will show a negative value. At this time, press [Tare] key to remove the tare weight value. Now, the weight window back to zero. © Adam Equipment Company 2019...
  • Page 12  “Lim-Lo” should now appear on the display with the same zero digits on the right of the display. Use the numeric keys to enter to low limit and press the [Q’TY/PST] key to confirm. © Adam Equipment Company 2019...
  • Page 13 When the quantity is shown on the quantity display, Press [M+] Key, and then enters the totalising function. The quantity display shows “Add XX “, XX means the Total Number of Additions. After 3 seconds, the scale will return to the counting mode. © Adam Equipment Company 2019...
  • Page 14 SKU ID can include letters, please check the step 6.5.2 for details on how to input. After inputting ID, press [PLU] to store. When finished, press [CE]   to exit. © Adam Equipment Company 2019...
  • Page 15 Connect the scale with PC by RS232, open ScaleSetPlu.exe, and choose the right port.   INGLE SETTING Press , software will show     Input the serial number, unit weight, SKU ID, name as follow picture. if need scale increase the serial number automatically, please choose “Auto inc”. © Adam Equipment Company 2019...
  • Page 16 DOWNLOAD MULTIPLE PLU BY TABLE (RECOMMEND)   Use table edit software (such as Excel, WPS, Numbers) to new built a file, then input PLU data by follow format:   Then save as xls file .    © Adam Equipment Company 2019...
  • Page 17 Communication address, effective in multi- 1-20 machine communication. T3 Bps Communication baud rate 2400, 4800, 9600, 19200, 38400, 56000, 115200 N81  T4 Fmt This parameter can be set to: n81 check bit/o71 O71  data bit /e71 stop bit. E71  © Adam Equipment Company 2019...
  • Page 18 To set if the scale can alarm when weight is 0. F9 FAL On means full alarm mode. OFF means simple alarm mode. F10 BC To set if the Hi-Lo relay runs after stable. Press ‘’ID’’ to escape and return to normal weighing mode. © Adam Equipment Company 2019...
  • Page 19 } the right weights to calibrate. LINEX Remark: In the second step, value of weights must bigger than the first step, and in the third step, value of weights must bigger than the second step. © Adam Equipment Company 2019...
  • Page 20 But need set P3 to OFF.)how to use and set this parameter, it is the same as standard calibration. P2 Ld1 The same as Ld0. P2 Lr0 The same as Ld0. P2 Lr1 The same as Ld0. © Adam Equipment Company 2019...
  • Page 21  Press the [Print/Save] button, this will take you into the system parameters (P1 FIL is to do with filtering) , press the [Print/Save] button again, and you should see the system parameter for settings capacity & divisions (P2 C-d), screen should look similar to as follows: © Adam Equipment Company 2019...
  • Page 22 P3 LIN (muli range calibration) – leave this set to OFF; if it is set to ON pressing the [M+] key toggles the setting.  Press the [Print/Save] key to go to calibration -P4 CAL © Adam Equipment Company 2019...
  • Page 23 NOTE: AE504 indicators will have the lb or kg indicator on, to show the unit of the weight requested. If the scale was in pounds before starting the calibration, the weights requested will be in pound values or if the scale was weighing in kilograms then metric weights will be requested. © Adam Equipment Company 2019...
  • Page 24  Labels can also be printed via the built-in printer when in the accumulation recall function and in parts counting. LABEL EDITING COMPUTER SOFTWARE The AE 504 is supplied with RS-232 interface which allows for connection between computer and indicator to edit labels for the inbuilt label printer and set printing parameters.
  • Page 25 Connect the indicator to the PC using the RS 232 cable provided, this is so the customised label can be downloaded straight to the indicator after completion Start up the label editing software             © Adam Equipment Company 2019...
  • Page 26 Prints:  How  many  labels  will  be  printed  when  the  print  button  is    pressed  To change the parameters, left click the desired parameter and a drop-down arrow will appear with different options to select from. 9.1.3 Label customisation   Once parameters have been set, the label can be customised and edited to  desired preference. © Adam Equipment Company 2019...
  • Page 27 Pictures can be added to a label design, the pictures will show as a black and white picture. To add a picture, left click the picture icon in the editing tools section.  The picture will appear as a small icon before uploading the image file via the parameter settings section. © Adam Equipment Company 2019...
  • Page 28   The barcode also has customisable parameters: Height: The height of the barcode  Thickness: Minimum line width  Barcode type: Type of barcode (food retailers usually use EAN13)  Readable:    Enable  or  Disable  the  Print  out  of  the  text  below  the  barcode  Rotation: Rotation angle (0 = clockwise)  Text: Can insert this variable (EAN13 barcodes must be numeric and    12 digits long. SKU must be 5 digits long, for price no dot needs to be  chosen)  © Adam Equipment Company 2019...
  • Page 29  Select the item you want to delete by left clicking it and press the delete button on the keypad.      A message will appear asking the user to confirm the deletion. Press ‘OK’ to confirm and the item will then be deleted from the label. © Adam Equipment Company 2019...
  • Page 30 RS-232 interface, outputs the weight, unit weight and count.  Specifications:  RS-232 output of weighing data ASCII code Adjustable Baud rate, 600, 1200, 2400, 4800, 9600 and 19200 baud 8 data bits No Parity © Adam Equipment Company 2019...
  • Page 31 All lines end with line feed <lf>, and carriage return <cr>characters. Data Format‐Normal Output <lf><cr>  <lf><cr>  ID  QTY            0 pcs         U. W           123 g     Kg or g for metric weights and lb for pounds.  G. W           1.234 Kg     Net Wt. if net weight is displayed  Item:                               [barcode]  <lf><cr>                    Includes 2 line feeds with carriage return  <lf><cr>          at beginning and end of  the form  DATE    12/09/2006                                    TIME 14:56  Data Format‐ Memory Recall Print:  <lf><cr>  ID  <lf><cr>  ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  TOTAL  No.                  5  Wt.           1.234 Kg    Pcs              10 pcs  <lf><cr>                         Includes 1 line feed  ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐  <lf><cr>           2 line feeds, carriage return  <lf><cr>  DATE    12/09/2006                                    TIME 14:56  © Adam Equipment Company 2019...
  • Page 32 Sets the zero point for all subsequent weighing. The display shows zero. Same as pressing the [Zero 0] key. P<cr><lf> Prints the weight, unit weight and totals same as pressing the [PRINT/ SAVE] key.   © Adam Equipment Company 2019...
  • Page 33   should be charged as soon as possible. Once the “LO bAT” message is shown the scale will still operate for about 10 minutes after which it will automatically switch off to protect the battery. © Adam Equipment Company 2019...
  • Page 34 Sets the backlight to be on at all times. Sets the backlight to operate automatically when a “BL Au” weight is placed on the scale or a key is pressed. “BL OFF” Sets the backlight to be off.   © Adam Equipment Company 2019...
  • Page 35 AD value exceed the pow Power on again after remove the ERR-Z er on zero range when po weights or re-calibrate wer on Low power alarm Charge battery Battery symbol flash Low power alarm Charge battery Lo-Bat © Adam Equipment Company 2019...
  • Page 36 AE504 model label 3.10.4.0.14808 12V 3A 36W power adapter 302408705 Mains cable figure of 8, UK 302408515 Mains cable figure of 8, Europe 302408514 Mains cable figure of 8, Australia 302408516 Mains cable figure of 8, SA © Adam Equipment Company 2019...
  • Page 37     ‐Contact telephone, e‐mail,        fax or any other methods:  B. Details of the unit purchased   (This part of information should always be available for any future correspondence.  We suggest you to fill in this form as soon as the unit is received and keep a print‐out in  your record for ready reference.) AE 504 _____ Model name of the scale:  Serial number of the unit:  Software revision number   (Displayed when power is first turned on):  Date of Purchase:  Name of the supplier and place: C. Brief description of the problem Include any recent history of the unit. For example:            ‐Has it been working since it’s delivered     ‐Has it been in contact with water    ‐Damaged from a fire    ‐Electrical Storms in the area    ‐Dropped on the floor, etc.   © Adam Equipment Company 2019...
  • Page 38          Repairs  carried  out  under  the  warranty  do  not  extend  the  warranty  period.  Components  removed during warranty repairs become company property.           The  statutory  rights  of  the  purchaser  are  not  affected  by  this  warranty.  The  terms  of  this  warranty is governed by the UK law. For complete details on Warranty Information, see the  terms and conditions of sale available on our web‐site.  © Adam Equipment Company 2019...
  • Page 39 As  we  often  update  adaptor  products  to    meet changing legislation it is not possible to refer to the exact model in this  manual. Please contact us if you need specifications or safety information for  your  particular  item.  Do  not  attempt  to  connect  or  use  an  adaptor  not  supplied by us.      © Adam Equipment Company 2019...
  • Page 40 Fax:  +27 (0)11 392 2587  Fax + 86 (27) 59420388  Fax +61 (0) 8 9456 4462  e‐mail:  e‐mail:   e‐mail:  sales@adamequipment.co.za  info@adamequipment.com.cn  sales@adamequipment.com.au        © Copyright by Adam Equipment Co.  All rights reserved.  No part of this publication may be reprinted or translated in  any form or by any means without the prior permission of Adam Equipment.  Adam  Equipment  reserves  the  right  to  make  changes  to  the  technology,  features,  specifications  and  design  of  the  equipment without notice.  All information contained within this publication is to the best of our knowledge timely, complete and accurate when  issued.  However, we are not responsible for misinterpretations which may result from the reading of this material.  The latest version of this publication can be found on our Website.www.adamequipment.com  © Adam Equipment Company 2019...