Download Print this page
Macnaught OCVF-001 Instruction Manual

Macnaught OCVF-001 Instruction Manual

35l oil control valve

Advertisement

Quick Links

35L Oil Control Valve
Instruction Manual
WARNING:
Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety
rules and other basic safety precautions may result in serious personal injury.
Save these instructions in a safe place and on hand so that they can be read when required.
Keep these instructions to assist in future servicing.
REV 02/23/22

Advertisement

loading
Need help?

Need help?

Do you have a question about the OCVF-001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Macnaught OCVF-001

  • Page 1 35L Oil Control Valve Instruction Manual WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Save these instructions in a safe place and on hand so that they can be read when required. Keep these instructions to assist in future servicing.
  • Page 2 GENERAL SAFETY REGULATIONS WARNING: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product, but must be supplied by the operator.
  • Page 3 TECHNICAL DETAILS Item No. OCVF-001 Inlet Connection 1/2" NPT(F) Fluid Range 1~35L/M(0.3~9.25gpm) Pressure Range 5-50Bar / 70-725psi Temperature Min. -10°C Max. 60°C Precision ±0.5% Viscosity 8-5000mps Power Source 1x3V CR2 battery Rigid Tube — Flexible Hose ■ Manual Tip —...
  • Page 4 2. CHANGE THE BATTERY • Battery type: Lithium CR2, 3V/1400mAh. • Change the battery like below when the battery signal is flashing on the display. • Remove the protector cover, unscrewing the screw. • Change the battery and screw the lid on again. USER BUTTONS The turbine digital meter features two buttons (MOVE and RESET) which individually perform two main functions and together, other secondary functions.
  • Page 5 • Show current correction factor and general total (See Fig. 5) Press MOVE and RESET together and hold for less than 3 seconds. Value “1.4000” is the correction factor which can be reset; “1234567” is the general total which cannot be reset.
  • Page 6 PROCEDURE FOR ENTER THE CORRECTION FACTOR DIRECTLY Carefully follow the procedure indicated below. FORMULA Proper correction factor = current correction factor×(actual value/ display value) Example: Actual value 20.75 Display value 18.96 Current correction factor 1.000 Proper correction factor 1.000×(20.75/18.96)=1.000×1.094=1.094 Wait for the meter to go standby. Reset the resettable total.
  • Page 7 MODIFY THE CORRECTION FACTOR IN FIELD PLEASE CAREFULLY FOLLOW THE PROCEDURE INDICATED BELOW. Wait for the meter to go standby. Reset the resettable total. Start dispensing into a measuring glass. Stop dispensing when over 5 Litres of volume is reached, read out the actual value.
  • Page 8 USAGE INSTRUCTION (1) Start: Turn on the trigger to make the oil transmission. (2) Keep the status: Push the lock ahead, then the transmission can be kept when the trigger is released. (3) Finish: a. If the lock is not used, release your hand, the trigger will turn off and finish the transmission.
  • Page 9 TROUBLE SHOOTING GUIDE Relieve the pressure before you check or repair the dispensing valve. Be sure all other valves and controls and the pump are operating properly. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the pressure relief procedure on page 3.
  • Page 10 3 years from date of purchase, but not including wearing parts. 2. Macnaught’s liability is limited to replacement or repair of defective material within the warranty period, when returned freight prepaid to the distributor or their designated service depot.
  • Page 11 EXPLODED AND PARTS LIST VALVE BODY EXPLORED DRAWING 4-10 4-11 4-12 4-13 4-14 4-15 4-16 4-17 4-18 Part No. Description Q’ty Part No. Description Q’ty Handle Body 4-10* Washer Trigger 4-11* Seal Grip 4-12 Slip Pole Screw 4-13* O Ring Trigger Lock 4-14* O Ring...
  • Page 12 Macnaught Americas (813) 628-5506 | info@macnaughtusa.com * Read Manual Before Use!