MUP-410
Digital DIN rail mounted signal
convertor
INPUT FOR POTENTIOMETERS
IN 1
OUT 1
Pot.
OMNI
Input
Power
HAZARD OF ELECTRICAL SHOCK
- Disconnect all power and other supply lines before servicing equipment
Failure to follow this instruction may result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Novotechnik Messwertaufnehmer OHG for any consequences arising out of the use of this device.
2
Connection
www.novotechnik.de
en
de
fr
es
fr
V
mA
DANGER
+
V
Analog
+
mA
output
-
-
Power supply
+
1
Description
cs
• Input for potentiometers
• Analog output
• Up to 7 200 measurements/s
• Quick configuration by DIP switch
it
• PC configurable via USB port
• Galvanic isolation 2.5 kVAC
• Simple instalation to DIN rail
4
Hi
3
Lo
EQUIPMENT OPERATION HAZARD
- Do not use this product in safety critical system
- Do not disassemble, repair or modify this product
- Do not operate beyond the recommended operating environment
Failure to follow these instructions may result in death, serious injury, or equipment damage.
Note
Contactors, high power electric motors, frequency drives and other power devices
should not be in a close proximity of the meter. Input signal leads (measured value)
should be seperated from all power lines and power devices. Even though the
device has been designed and tested according to standards for industrial environ-
ment, we strongly advise to adhere to the above presented rules.
1 / 4
LED Indication
Hi
Lo
Status
Device is running
1
Device functionality is limited, powered via USB
This device has a Delayed Start option
2
Error: device is out of order
Tare function is activated
Error: of input (> ±110% of range) or of sensor
[ERR.1]
Error: AO loop open [ERR.10]
Error: setting / calibration [ERR.34-36]
Serious error (Safe mode) [ERR.50]
1
Button function is blocked
Simulation mode is activated
WARNING
0,05...2,5 mm
30...12 AWG
Ø 3,5 mm
Ø 0.14 in
OMNI
LINK
Legend
① Connectors
② Control button
③ RGB Status LED
④ microUSB port for PC connection
2
8
0.32
1,5 Nm
13.2 lb-in
MINI-TECHDOK - MUP-410_AO - 2023.1.0 - en
Need help?
Do you have a question about the MUP-410 and is the answer not in the manual?