Daikin ComfortNet DX18TC Service Instructions Manual page 19

Condensing units, split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Hide thumbs Also See for ComfortNet DX18TC:
Table of Contents

Advertisement

ACCESSORIES
MODELS
HKR-03*
HKR-05*/-05C*
AVPTC183014A*
X
AVPTC313714A*
X
AVPTC426014A*
X
*
Revision level that may or may not be designated.
C
Circuit breaker option.
NOTE:
When 8kW and 10kW heat kits are used with an AVPTC1830 and AVPTC3137, matched with 2- ton outdoor unit, see Note 1 below.
1
Set Heater Kit dip switches 9, 10 and 11 to 6kW setting (9-ON, 10-OFF,11-ON) to obtain 840 CFM.
2
This heater kit can only be used for '1000 CFM or higher' applications.
3
This heater kit can only be used for '1200 CFM or higher' applications.
ELECTRIC HEAT KIT APPLICATIONS - AVPTC
HKR-06*
HKR-08*/-08C*
1
X
X
X
1
X
X
X
X
X
X
HKR-10*/-10C*
HKR-15C*
HKR-20C*
1
X
---
---
1
X2
---
X
X
X
X3
HKR-21C*
HKA-15C*
HKA-20C*
---
---
---
2
---
X
X
3
X3
X
X
19