  • Page 1 OWNER’S GUIDE Wireless RF Control Kit IT-36003 DO NOT THROW AWAY! OWNER’S GUIDE CONTAINS IMPORTANT INFORMATION. LEAVE WITH HOMEOWNER...
  • Page 2: Table Of Contents

    4. Follow Instructions - All installation and operating instructions should be followed. 5. Water – The QuietCool system should not be used near water. If you live in a very humid climate, be sure to cover your damper box with insulation to reduce condensation.
  • Page 3: System Overview

    The QuietCool Whole House Fan RF Wireless Control is the simplest way to control your QuietCool Advanced Whole House Fan from anywhere in your home! The QuietCool RF Wireless Control allows users to set the length of time that the fan will run and set the desired speed level.
  • Page 4: Installation

    Install the Hub directly to the motorhead: Remove the handy box cover on your QuietCool fan. Remove the wire nuts from the power cord and motor wires inside the handy box. Remove the ground screw.
  • Page 5 Connect the white wire from the power cord and the white wire on the fan to the white wire from the Hub. Cap the yellow and red wires from the Hub. FOR TRIDENT AND CLASSIC MODELS: Connect the red wire from the fan to the blue wire on the Hub FOR STEALTH AND ENERGY SAVER MODELS: Connect the black wire from the fan to the blue wire on the Hub...
  • Page 6 Test button again and the fan will switch to low speed. Press the Test button again and the fan should shut off and the LED will be off. If the fan doesn’t operate as described in step 7, please check the dip switch postion. 1-888-QUIETCOOL...
  • Page 7 Figure C Attach green ground wires to ground screw Set dip switches: 1 - OFF 2 - ON 3 - OFF POWER TIMER TEST PAIR Whole House Fan Power Cord All White Common Wires Together Two Speed Wiring (for ES-3100, 4700, 5400, 6000, 7000, and STL PRO-3.3) (see Figure D) Using a wire nut, connect the black wire from the power cord and the black wire from the fan to the black wire from the Hub.
  • Page 8 If the fan doesn’t operate as described in step 9, please check the dip switch postion. Figure E Attach green ground wires to ground screw Set dip switches: 1 - OFF 2 - OFF 3 - ON POWER TIMER TEST PAIR Whole House Fan Power Cord All White Common Wires Together 1-888-QUIETCOOL...
  • Page 9: Fan Hub Led Indicators

    Fan Hub LED Indicators Power Indicator • The Power LED indicator will always be lit when the Hub is connected to Power. • If this LED is not lit, check the power source Timer Indicator POWER TIMER TEST PAIR • The Timer LED indicator will light up as shown below: 1 Hour: 1 Blink 2 Hours: 2 Blinks...
  • Page 10: Pairing The Wall Switch

    If the fan comes on, this is a good location. If all the LED indicators turn on, the Wall Switch is not communicating with the Hub and you will need to find a location closer to the fan. 1-888-QUIETCOOL...
  • Page 11: Installing The Wall Switch

    Installing the Wall Switch Using your hands, slide the Wall Switch off the mounting plate. 1 2 4 8 12 If you have an existing Wall Switch with a junction box installed, install the mounting plate over the junction box using the oblong holes on the mounting plate.
  • Page 12: Frequently Asked Questions

    Will my neighbor be able to control my fan if they have the same set up as me? They will not because you need to physically activate the pairing process between the RF Switch and the RF Hub. What is the range? The RF Switch and RF Hub have a range restriction of 100ft. 1-888-QUIETCOOL...
  • Page 13 Why is there a medium speed if my fan is only a two speed? The RF Hub and RF Switch are universal to all QuietCool models. There are some units that feature three speeds which use the medium on the switch. As long as your DIP switch is set correctly in the hub, the switch will automatically skip over medium speed.
  • Page 14 No subsequent purchaser of the unit or of a home in which it is installed is entitled to any of the benefits of this warranty. The QuietCool Product that you have purchased has a limited warranty from the date of purchase against defects in workmanship and materials.
  • Page 15: Qc Manufacturing, Inc

    Temecula, CA 92591 www.QuietCoolSystems.com 951-325-6340 Rev. 6/12/23 FCC SUPPLIER’S DECLARATION OF QC MANUFACTURING, INC. PHONE CONFORMITY 26040 Ynez Road 1-888-QUIETCOOL Temecula, CA 92591 PRODUCT NAME: RF Glass Switch MODEL NUMBER: IT-RFGLSSWITCH-01 WEBSITE EMAIL www.quietcoolsystems.com info@quietcoolsystems.com FCC Regulations This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 16 Rev. 6/12/23 1-888-QUIETCOOL | WWW.QUIETCOOLSYSTEMS.COM...