Sharp AR-285 Service Manual page 165

Hide thumbs Also See for AR-285:
Table of Contents

Advertisement

Trouble code
Main
Sub
code
code
U9
00
Content Operation control communication trouble
(ICU detection)
Detail
Communication setup error,
framing/parity/protocol error
Cause
Slave unit PWB connector improper
connection
Slave unit PWB – ICU PWB harness
trouble
Connector pin breakage of the motor
PWB of the slave unit PWB
Slave unit ROM trouble. no ROM, ROM
reverse insertion, ROM pin breakage
Check
Connect the connector of the slave unit
and
PWB and the ICU PWB.
remedy
Check the connection and the harness.
Check the grounding of the copier.
Check the ROM of the slave unit PWB.
90
Content Operation control communication trouble
(OPE detection)
Detail
Communication setup
error/framing/parity/protocol error
Cause
Slave unit PWB connector improper
connection
Slave unit PWB – ICU PWB harness
trouble
Slave unit PWB mother board connector
pin breakage
Check
Check the slave unit PWB and the ICU
and
PWB connector connection.
remedy
Check the copier earth.
EE
EL
Content Auto developing adjustment trouble
(overtoner)
Detail
A sample data is less than 0 when auto
developing adjustment is executed.
Cause
Toner density sensor defective
Charging voltage or developing voltage
improper.
Toner density improper
Developing unit defective
PCU PWB defective
Check
Make auto developing adjustment with
and
SIM25-2.
remedy
EU
Content Auto developing adjustment trouble
(undertoner)
Detail
A sample data is less than 99 when auto
developing adjustment is executed.
Cause
Toner density sensor defective
Charging voltage or developing voltage
improper
Toner density improper
Unit defective
PCU PWB defective
Check
Make auto developing adjustment with
and
SIM25-2.
remedy
Description
Trouble code
Main
Sub
code
code
FC
00
Content ASK/IrDA modulation LSI reset error
Detail
Cause
Check
and
remedy
01
Content ASK/IrDA switch error
Detail
Cause
Check
and
remedy
PF
00
Content RIC copy inhibition command reception
Detail
Cause
Check
and
remedy
––
Content Auditor not ready
9 – 10
AR-505
Description
Though the RESET signal pulse is sent
to the ASK/IrDA modulation LSI, the
power signal is not turned ON.
1) ICU main PWB defect
2) ASK/IrDA modulation LSI/Clock
oscillator defect
Perform the self diag with SIM 68-01.
Replace the ICU main PWB.
Though the ASK/IrDA switch command is
sent to the ASK/IrDA modulation LSI, the
AI signal is not changed.
1) ICU main PWB defect
2) ASK/IrDA modulation LSI/Clock
oscillator defect
Perform the self diag with SIM 68-01.
Replace the ICU main PWB.
Copy inhibition command received from
RIC (host)
Judged by the host.
Notice to the host
8/6/1999

Advertisement

Table of Contents
loading

Table of Contents