Download Print this page

Randell 9872SCA Specifications page 14

Drop-in wrapped coldwall cold pan
Hide thumbs Also See for 9872SCA:

Advertisement

LEGEND FOR
MODEL # 9580-2A
(1) ELEMENT, 1100 WATTS
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 5.3Amps
120/240V-60Hz-1Ph 4.5Amps
1/4hp COMPRESSOR
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
20"
9"
6"
18.25"
22"
26"
CUTOUT DIMENSION
1" HIGH PERFORATED
27.75" X 22.5"
S/S BOTTOM
25.25"
27.25"
31.25"
MODEL #9580-2A
LEGEND FOR
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 21.2Amps
J
HP
120/240V-60Hz-1Ph 18.3Amps
1/4hp COMPRESSOR
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
20"
9"
6"
18.25"
22"
26"
CUTOUT DIMENSION
65.75" X 22.5"
63.25"
27.25"
65.25"
69.25"
MODEL #9580-5A
12"x20"
Model
L
D
Pan Cap.
9580-2A
31 1/8"
26"
2
9580-3A
43 5/8"
26"
3
9580-4A
56 1/2"
26"
4
9580-5A
69 1/4"
26"
5
Requires 120 / 240V or 120/208V (4 wire) power supply hard wiring to "J" box. 120V refrigeration system - 208/240V heating system.
Randell, Unified Brands 888-994-7636, fax 888-266-5244
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
LEGEND FOR
MODEL # 9580-3A
(2) ELEMENTS, 2200 WATTS
LEGEND FOR
REQUIRES HARDWIRE CONNECTION
MODEL # 9580-2A
120/208V-60Hz-1Ph 10.6Amps
(1) ELEMENT, 1100 WATTS
120/240V-60Hz-1Ph 9.2Amps
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 5.3Amps
1/4hp COMPRESSOR
120/240V-60Hz-1Ph 4.5Amps
D
1" DIA DRAIN LINE CONNECTION
1/4hp COMPRESSOR
1" FPT AT 24" AFF
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
20"
9"
20"
6"
9"
6"
18.25"
18.25"
22"
26"
22"
26"
CUTOUT DIMENSION
1" HIGH PERFORATED
40.25" X 22.5"
S/S BOTTOM
37.75"
CUTOUT DIMENSION
1" HIGH PERFORATED
27.75" X 22.5"
S/S BOTTOM
25.25"
27.25"
39.75"
43.75"
27.25"
MODEL #9580-3A
31.25"
MODEL #9580-2A
D
J
HP
1" HIGH PERFORATED
S/S BOTTOM
Cut Out Size
No. of
Unit
Control Panel Elements Watts
27 3/4" x 22 1/2"
14" x 6"
40 1/4" x 22 1/2"
14" x 6"
53" x 22 1/2"
14" x 6"
65 3/4" x 22 1/2"
14" x 6"
LEGEND FOR
MODEL # 9580-4A
(3) ELEMENTS, 3300 WATTS
LEGEND FOR
REQUIRES HARDWIRE CONNECTION
MODEL # 9580-3A
120/208V-60Hz-1Ph 15.9Amps
(2) ELEMENTS, 2200 WATTS
120/240V-60Hz-1Ph 13.3Amps
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 10.6Amps
1/4hp COMPRESSOR
120/240V-60Hz-1Ph 9.2Amps
D
1" DIA DRAIN LINE CONNECTION
1/4hp COMPRESSOR
1" FPT AT 24" AFF
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
20"
9"
20"
6"
9"
6"
18.25"
18.25"
22"
26"
22"
26"
CUTOUT DIMENSION
53" X 22.5"
50.5"
CUTOUT DIMENSION
1" HIGH PERFORATED
40.25" X 22.5"
S/S BOTTOM
37.75"
27.25"
52.5"
27.25"
56.5"
MODEL #9580-4A
39.75"
43.75"
MODEL #9580-3A
D
H.P. 120V (Refrig.) 208V (Heated) 240V (Heated) Ship Wt.
1
1100
1/4
5.3
2
2200
1/4
5.3
3
3300
1/4
5.3
4
4400
1/4
5.3
Models 9580A
LEGEND FOR
MODEL # 9580-5A
(4) ELEMENT, 4400 WATTS
LEGEND FOR
REQUIRES HARDWIRE CONNECTION
MODEL # 9580-4A
120/208V-60Hz-1Ph 21.2Amps
(3) ELEMENTS, 3300 WATTS
120/240V-60Hz-1Ph 18.3Amps
REQUIRES HARDWIRE CONNECTION
120/208V-60Hz-1Ph 15.9Amps
1/4hp COMPRESSOR
120/240V-60Hz-1Ph 13.3Amps
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
1/4hp COMPRESSOR
D
1" DIA DRAIN LINE CONNECTION
1" FPT AT 24" AFF
20"
20"
6"
9"
6"
18.25"
22"
26"
22"
26"
CUTOUT DIMENSION
1" HIGH PERFORATED
65.75" X 22.5"
S/S BOTTOM
CUTOUT DIMENSION
53" X 22.5"
50.5"
27.25"
27.25"
MODEL #9580-5A
52.5"
56.5"
MODEL #9580-4A
Amps / 60 / 1 PH
5.3
4.5
110
10.6
9.2
135
15.9
13.8
160
21.2
18.3
185
MO
(4) ELE
REQUIRES H
120/208
120/240
1/4hp C
D
1" DIA
1" FPT AT
9"
18.25"
1" HIGH PERFORATED
S/S BOTTOM
63.25"
1" HIGH PERFORATED
S/S BOTTOM
65.25"
69.25"
MODEL #95

Advertisement

loading