Sony FCB-EX1000 Technical Manual page 17

Color camera module
Hide thumbs Also See for FCB-EX1000:
Table of Contents

Advertisement

Grid
Use the grid displayed on the screen to set mask
positions (see the figure below).
By executing the Center Line On command, only the x
and y axes of the center are displayed. Grids lines
disappear.
Alarm Function
This function instructs the camera to detect movement
within the monitoring area and then send an alarm
signal automatically.
A High level signal is output when camera detects
movement inside the monitoring area. A Low level
signal is output when object stops moving.
However, when the mode is set to "DAY/NIGHT", the
14hex (20(10))
High level signal is output for dark and the Low level
signal is output for bright.
14hex (20(10))
The Detect signal goes out through the serial command
(VISCA) communication line.
Example
1. A door is motionless, so the Detect Level is Low.
2. At the moment when the door is opened by
3. The Detect Level is High while the shooting object
4. When the door is closed, Detect Level goes to Low
someone, the Detect Level goes to High.
is moving.
again, or signals are output only once at the time of
switching between High Level and Low Level.
Basic Functions
17