AH1 (FJ) Miniature Switches

CAUTIONS FOR USE

■ Fastening of the switch body
1) Use M2 screws to attach switches with
Max. 0.098 N·m torque. Use of screw
washers or adhesive lock is
recommended.
2) When the operation object is in the
free position, force should not be applied
directly to the actuator or to the pin
plunger. Also force should be applied to
the pin plunger from vertical direction to
the switch.
3) In setting the movement after
operation, the overtravel "OT"should be
set from 70% to 100%. Setting the
movement less than 70% may cause
degrading of the electrical mechanical
performance.
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
■ Selection of switch
Please make your selection so that there
will be no problems even if the operating
characteristics vary up to ±20% from the
standard values.
■ Soldering operation
Perform soldering in less than 3 seconds
with maximum 350°C iron. Care should
be taken not to apply force to the
terminals during soldering. We
recommend a soldering iron with
temperature adjustment in order to
prevent poor quality soldering.
Please consult us if you intend to use a
soldering iron of 60 W or higher.
6
■ When switching low-level current
and voltage, AgNi alloy + Au-clad
contact type is recommended.
■ Environment
Locations where corrosive gases having
a bad influence on contacts are present,
and locations where there is an
excessive amount of siliceous or other
abrasive dust should be avoided.