• All modules must be installed by licensed electricians. • Electricians must take precautions about occupational health and safety. • All Set Solar PV module have junction box, wires and connectors so PV module do not need any extra wires.
1.2. INSTALLATION SAFETY • Insulated gloves must be worn when carrying the PV module. • Insulated tools should be used for electrical connections. • Inappropriate transportation or installation can cause the panel to become damaged. • Please do not lift PV module from junction box or wires.
Set Solar modules is Class C. 2. LIMITATION OF LIABILITY Set Solar is not responsible for any kind of damage, including but not limited to module operation and system installation error, and personnel injury, hurt, and property loss caused by failure to following the instructions in this Manual.
Page 6
• Set Solar PV modules operate at temperatures between -40°C and +85°C . • Module electrical ratings are measured under Standard Test Conditions (STC) of 1000 W/m2 irradiance, with an AM1.5 spectrum, and a cell temperature of 25°C. The module might produce more or less voltage or current than rated value in uncertainty condition.
For different projects there are different mounting angles. Set Solar recommends that the mounting tilt angle should not be less than 10°, or in accordance with local regulations or follow the recommendations of experienced PV module...
4.3. MOUNTING 4.3.1. Mounting Using Frame Bolts Holes Each module must be securely fastened using a minimum of 4 mounting holes (9mm×14mm) at locations shown below. For maximum security against strong winds and heavy snow falls, all 10 mounting holes should be used to secure the module. ➢...
4.3.2. Mounting with Clamps The module clamps should not come into contact with the front glass and must not deform the frame. Be sure to avoid shadowing effects from the module clamps. The module frame is not to be modified under any circumstances. When choosing this type of clamp-mounting method, please be sure to use at least four clamps on each module.
Module Type Module Dimensions(AxB) J (mm) K (mm) SETM60 1665x1002 SETM72 1979x1002 SETM120 1755x1038 SETM144 2094x1038 5. WIRING Modules are supplied with cables and connectors to be used for system electrical connections. It is not recommended to use modules with different configurations and electrical characteristics in the same system.
The maximum number of series connected modules depends on system design, the type of inverter used and environmental conditions. It should be noted that modules must not be connected together to create a voltage higher than the permitted system voltage. There is no limitation on the number of modules that can be connected in parallel;...
7. MAINTENANCE AND REPAIR • A buildup of dust or dirt on the module(s) front face will result in a decreased energy output. Clean the panel(s) preferably once per year if possible (depend on site conditions) using a soft cloth dry or damp, as necessary. Water with high mineral content may leave deposits on the glass surface and is not recommended.
Need help?
Do you have a question about the Volta SETM60 and is the answer not in the manual?
Questions and answers