Ebyte E22-400T30S User Manual page 19

Sx1262 433/470mhz 1w lora wireless module
Hide thumbs Also See for E22-400T30S:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.
1
After setting the relay mode through the configuration mode, switch to the general mode and the relay starts to work.
In repeater mode, ADDH and ADDL are no longer used as module addresses, but are forwarded and paired corresponding to NETID
2
respectively. If one of the networks is received, it will be forwarded to another network; the network ID of the repeater itself is invalid.
3
In relay mode, the relay module cannot send and receive data, and cannot operate with low power consumption.
When the user enters other modes from mode 3 (sleep mode) or during the reset process, the module will reset the user parameters, during
4
which AUX outputs low level.
Relay networking rules description:
1、Forwarding rules, the relay can forward data in both directions between two NETIDs.
2、In relay mode, ADDH\ADDL is no longer used as a module address, but as a NETID forwarding pair.
As shown in the picture:
First Relay
1
"Node 1" has a NETID of 08.
"Node 2" has a NETID of 33.
The ADDH\ADDL of trunk 1 are 08 and 33 respectively.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
Secondary Relay
2
The ADDH\ADDL of relay 2 are 33 and 05 respectively.
So relay 2 can forward the data of relay 1 to network NETID:05.
Thus node 3 and node 4 can receive node 1 data. Node 4 outputs data normally, and node 3 has a different address from node 1, so no
data is output.
Two-way Relay
3
Configuration as shown in the figure: the data sent by node 1 can be received by nodes 2 and 4, and the data sent by nodes 2 and 4 can
also be received by node 1.
Copyright ©2012–2020, Chengdu Ebyte Electronic Technology Co., Ltd.
18
E22-400T30S_User Manual _EN

Advertisement

Table of Contents
loading

Table of Contents