  • ENGLISH, page 1
PROBLEMA
El LED verde parpadea
y en la pantalla muestra
CHARGE ABORTED-
BAD BATTERY.
La pantalla muestra
CONNECT CLAMPS.
18. ESPECIFICACIONES
Entrada .......................................................................................... 230 V CA~50 Hz, 0,6 A
Salida .................................................................................................................12 V
Tensión de carga................................................................................................14,2-14,4V
Dimensiones: Al x An x L ..........................................................194 mm x 89 mm x 83 mm
Peso ........................................................................................................................ 0,78 kg
Protección de salida.........................................................................................................Sí
Protección de polaridad diversa, a prueba de chispas/arcos ..........................................Sí
Grado de protección de entrada ..................................................................................IP64
CAUSA POSIBLE
La batería es demasiado grande
para el cargador.
El voltaje de la batería todavía está
debajo de 10 V después de 2 horas
de carga.
Las pinzas no están llevando a cabo
una buena conexión.
El fusible está quemado.
Usted necesita un cargador con
una velocidad amperios más alta.
Compruebe la batería.
Compruebe si hay una conexión
pobre en la batería o en la estructura.
Reemplace el fusible en línea para
el conector de anillo.