Page 2
INDEX Page No. Chapter Sr. No Gratitude........... Unpacking ............Installation Procedure ........Technical Data of Scale......Connections ........... Key Operation ......... Scale Functions ..........User Parameter Setting Mode ......Maintenance and Attention ......Warranty Card ..........Other Products ..........PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES Survey No.
Page 3
Weighing Scales that we confidently recommend based on over 97 years of Weighing Scale manufacturer. While these models are of course capable of fast and accurate weighing, the ECON Series models all use the High Precision Load Cells and highly reliable electronic boards...
Chapter 4. Technical Data Of Scale 1. Series - ECON Series 2. Serial communication interface - RS-232 signal 3. Transmission distance - <20m 4. Power supply - AC240V;50Hz (-2%~+2%) 5. Operating temperature - (-10°C to 50°C) 6. Relative humidity - ≤85%RH 7.
Chapter 6. Key Operations 1. Zero Key: Used to zero the weight on scale. It operates up to 4% of scale capacity only; as per Weights and Measure law. The key is also used as left increment key. 2. Tare Key: Used to Tare the weight. The key is also used as decrement key.
Page 6
Enter in to Counting Mode: 1. Place the counted samples on the pan. 2. Press [Func] key the display will show [S 0]. Select the options listed above. (If the samples kept on the pan are 10nos) 3. Press [Func] key again to change the option and select [S 4.
Page 7
2. Weight Accumulation: When scale is in weighing mode press [M] key the accumulation of displayed weight is done. On releasing the [M] key the display will show [Add xxx](Add xxx where xxx = number of times the weight has been accumulated) for 1sec and then accumulated weight for 2sec then scale will come back to weighing mode.
Page 8
Chapter 8. User Parameter Setting Mode In weighing mode, keep [FUNC] key pressed for 5 sec, it will enter operator setting mode, press [M] to choose the mode, press [TARE] to move forward and press [ZERO] to move reverse the parameter. Pressing the [FUNC] key will make you escape to previous menu or stage.
Page 9
Auto Tare function A-trE trE-y trE-n Power ON Zero function Pn-Zro Zro-y Zro-n Peak Hold Function P-HLd HLd-y HLd-n HLd-P Auto Sleep Time A-SLP SLP-00 to 99 Zero Lock Counts Zr-Loc Loc-00 to 99 Stable Time Lr-FAt 0.974 Stable Time Stb-t Stb-1 Stb-2...
Page 10
1. Display Speed Selection [d-SPd]-The scale have 5 different display update speeds. SPd-1 is the fastest and SPd-5 is the slowest speed. To set Display Speed: a. Enter in to User Parameter Setting Mode showing Display Speed Selection b. Press [M] key to select display speed c.
Page 11
[tr-13] - this mode of transmission is used to connect a scoreboard to indicator. PRINT Keys – Press [N/G] and [FUNC] keys simultaneously. e.g. If my selected data transmission format is tr-01 then data will be transmitted when print key is pressed on scale and in the format (=002.000) weight only.
Page 12
4. RS-232 Output Data – The scale have 3 data available on RS-232 as explained below. To set RS-232 Output Data: a. Enter in to User Parameter Setting Mode b. Using [TARE] & [ZERO] keys select d-OUt c. Press [M] key to select RS-232 Output Data parameter d.
Page 13
6. Power ON Zero [Pn-Zro] - The Scale have Power ON Zero function as explained below. Power On Zero mean zeroing the weight on the scale during power On only if the weight during power on is less than 20% of Scale capacity.
Page 14
d. Scale always shows previously set Peak Hold. Using [TARE] & [Zero] keys select HLd-y, HLd-n or HLd-P. e. Press [M] key to confirm the selection f. Use [FUNC] key to escape from selection Note: Pressing [FUNC] key it should back to Peak Hold. If without selection escaped out then scale will work on previous setting.
Page 15
To set Zero Locking: a. Enter in to User Parameter Setting Mode b. using [TARE] & [ZERO] keys select Zero Locking c. Press [M] key to select Zero Locking d. Scale always shows previously set Zero Locking Value. Using [TARE] for DECREASE, [ZERO] for INCREASE and [N/G] for SHIFT can change the Zero Locking Value.
Page 16
To set Stable time: a. Enter in to User Parameter Setting Mode b. Using [TARE] & [ZERO] keys select Stb-t c. Press [M] key to select Stable Time parameter d. Scale always shows previously set Stable time. Using [TARE] & [ZERO] keys select from Stb-1 to Stb-3.
Chapter 7. Mentainance And Attentions 1. To guarantee its accuracy, the scale should not be placed directly under sunshine and should be set on the firm and leveled place. 2. It is not suitable to place the scale in the dusty and vibration environment and also avoid using in the moist environment.
Warranty Information EAGLE offers a Limited Warranty (Parts and Labour) for the components that fail due to defects in materials or workmanship. Warranty starts from the date of purchase up to 12 months . During the warranty period, should any repairs be necessary, the purchaser must inform its suppler or EAGLE Company.
Page 19
OTHER EAGLE PRODUCTS Precision Analytical Scales Table Top Scales Platform Scales Hanging Scales Crane Scales Pallet Scale LifeStyle Scales PROVIDER OF LIFE STYLE & INDUSTRIAL SCALES Survey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110,...