CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND
FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS - SEE NAME PLATE AND INSTRUCTIONS
THIS STOVE MUST BE INSTALLED IN CONJUNCTION WITH THE REQUIREMENTS OF BSEN 15287-
1:2007 – DESIGN INSTALLATION AND COMMISSIONING OF CHIMNEYS.
WARNING NOTE:
Properly installed, operated and maintained this stove will not emit fumes into the dwelling.
Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is
potentially dangerous and must not be tolerated. If fume emission does persist, then the following
immediate action should be taken:-
a) Open doors and windows to ventilate the room and then leave the premises.
b) Let the fire go out.
c) Check for flue or chimney blockage and clean if required.
d) Do not attempt to relight the fire until the cause of the fume emission has been identified
and corrected. If necessary seek expert advice.
The most common cause of fumes emission is flueway or chimney blockage. For your own safety
these must be kept clean at all times.
A CO detector must be fitted in the same room as this appliance to conform to UK requirements of
installation.
The Clean Air Act 1993 and Smoke Control Areas
"Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any
fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel"
for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls
which generally apply in the smoke control area). The Secretary of State for Environment, Food and Rural
Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control
areas in England. In Scotland and Wales this power rests with Ministers in the devolved administrations for
those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland.
Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been "authorised"
in Regulations and that appliances used to burn solid fuel in those areas (other than "authorised" fuels) have
been exempted by an Order made and signed by the Secretary of State or Minister in the devolved
administrations. Further information on the requirements of the Clean Air Act can be found here :
http://smokecontrol.defra.gov.uk/Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can contact them for details of Clean Air
Act requirements "The Ecco Stoves 580EC2 has been recommended as suitable for use in smoke control areas
when burning wood logs with a maximum moisture content of 20%" seasoned wood logs only.
Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom
T | +44 (0) 1527 857 814
SAVE THESE INSTRUCTIONS
TESTED TO: EN13240
E |
sales@eccostove.com
For all patents – See Addendum
580/03.05.23/V2
P a g e |
W | www.eccostove.com
1 of 29

Advertisement

Table of Contents
loading

Summary of Contents for ECCO STOVE 580EC2

  • Page 1 Clean Air Act requirements “The Ecco Stoves 580EC2 has been recommended as suitable for use in smoke control areas when burning wood logs with a maximum moisture content of 20%” seasoned wood logs only.
  • Page 2 24. GENERAL AND HEALTH AND SAFETY 25. PARTS LIST a) PARTS DRAWING 26. WARRANTY Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 3: Warranty Registration

    P a g e | 3 of 29 27. WARRANTY REGISTRATION 28. PAINTED MODEL NOTE Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 4 Netherlands: №: 2 213 945 (E) Russia: №: 2 213 945 (E Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 5 – not all chimneys are suitable. The Ecco Stove 580EC2 is tested for use with wood logs – you must check with your local area authority to ensure it is permissible to burn wood logs in the area where the stove is to be installed.
  • Page 6 Radiant heat is omitted from the outer surfaces and initial heat from the glass door panel. 4. FLUE OUTLET (150 DIAMETER) Your Ecco Stove 580EC2 is delivered with a top flue outlet only. If the installation demands, a 45° bend may be taken from the top of the stove and back into the chimneys flue.
  • Page 7: Ash Grate

    Load the stove with care. 8. ASH GRATE The cast iron grate within your Ecco Stove 580EC2 is highly durable but will be damaged if ash is allowed to build up in the grate bars. Ash build up will also impair the stoves primary combustion as the air flow will be choked.
  • Page 8: Air Controls

    2. Secondary air down the face of the glass 3. Tertiary air through the same pre drilled back boards. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 9: Closing Down

    Close the drawer at optimum temperature for automatic operation to continue. f) CLOSING DOWN Your Ecco Stove 580EC2 will continue in combustion at all times. No facility to shut it down exists. Close the flue damper if fitted (only after combustion is completed).
  • Page 10: Initial Firing

    UNDER FIRING WARNING When re lighting; re fuelling or re firing the Ecco Stove 580EC2, it must be fired up to 160°C or above in order that each new wood load turns into proper combustion – if allowed to “tick over”...
  • Page 11: Continuous Burning

    The stove may be run as such for as long as needed. Your Ecco Stove 580EC2 is not designed to stay in for long periods or overnight.
  • Page 12: Ash Removal

    12 of 29 14. ASH REMOVAL Ash removal must only be carried out when your Ecco Stove 580EC2 is not alight as removing the ash drawer would over fire the appliance. Remove the ash drawer fully for emptying but ensure it is re fitted to follow the lighting procedure at 13a in this manual.
  • Page 13 16. RE FUELLING After 1 hour or so hours burning your Ecco Stove 580EC2 will need re fuelling. The fuel load for each firing is 2 logs on a full 1.4 kg charge – subject to how you intend to run the stove and the heat output you are looking for.
  • Page 14: Cleaning And Maintenance

    Clean the door glass to remove fly ash or tar deposits with a propriety glass cleaner or a damp cloth and the ash from the fire box. a) CATALYSER – The 580EC2 only is fitted with a catalyser in the head of the stove above the baffle system.
  • Page 15: Paint Finishes

    Never respray the stove body when the stove is in fired use or hot. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 16 Place the grate section on and bump into position with a rubber mallet to bed in. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 17 Door and Frame Slide the door section down Into place between the side sections ready for the lower top to be fitted. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 18 Lower baffle viewed from above Lower baffle with catalyser baffle viewed from below Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 19 Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 20 Air Supply – 9 sq centimetres required within the UK (Refer to ADJ2010) Outside the UK to those countries of local area requirements. d) Extractor Fans: No extractor fans are to be fitted into the same room as the Ecco Stove. e) Flue Draught: Minimum cold flue 10 pascals f) Flue gas mass flow: 5.6...
  • Page 21 Dispose of the items correctly i.e. separate the parts to be disposed of in material groups. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 22: Health And Safety

    If the alarm sounds follow the instructions given under warning on the first page of this manual. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 23: Parts List

    SP30 Vermiculite plug inc 1mm hole Glass clips - handle side GLC51 Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 24: Parts Drawing

    In the event of a chimney fire, the fire door and ash pan must be tightly closed and the local fire brigade alerted immediately. e) The Ecco Stove 580EC2 when used slowly releasing heat may be left after its last firing for many hours with the stove pipes damper (if fitted) closed to slowly release heat into the house on a falling heat.
  • Page 25 Clearance Distance to Combustibles - Rear 150mm Clearance Distance to Combustibles - Side 450mm Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 26 The Product = The Ecco Stove 580EC2. 1. Please read your user instructions to ensure that you get the best from your Ecco Stove 580EC2. Operating it properly is essential for this type of appliance to get the correct results. Always ask for help if you are unsure 2.
  • Page 27 Paint finishes will change colour with use. This warranty does not cover such changes. 8. Fuels The warranty only applies to the use of wood logs on your Ecco Stove 580EC2. Coals or processed petro chemical fuels void the warranty as their use may produce blockage in flueways.
  • Page 28: Installation Details

    Upon completion of this form please send it to Landy Vent UK Ltd, Foster House, 2 Redditch Road, Studley, B80 7AX, UK. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 29 29 of 29 Painted finish note: As the Silicon Carbide masonry body of the Ecco Stove will absorb both temperature and moisture it is possible that in certain environments of high humidity or where condensation is present either in the surroundings or within the flue, it can cause paint to bubble or flake on the stoves outer body.