Advertisement

Quick Links

ECCO STOVE MODEL 678EC and E850 Manual
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS – SEE NAME PLATE AND INSTRUCTIONS.
WARNING NOTE:
Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes
from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must
not be tolerated. If fume emission does persist, then the following immediate action should be taken:-
a) Open doors and windows to ventilate the room and then leave the premises.
b) Let the fire go out.
c)
Check for flue or chimney blockage and clean if required.
d) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.
If necessary seek expert advice.
The most common cause of fumes emission is flueway within the stove or chimney blockage. For your own safety
these must be kept clean at all times.
A CO detector must be fitted in the same room as this appliance to conform to UK requirements of installation.
The Clean Air Act 1993 and Smoke Control Areas
"Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed
boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use
within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which
generally apply in the smoke control area). The Secretary of State for Environment, Food and Rural Affairs has
powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England.
In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries. Separate
legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement
that fuels burnt or obtained for use in smoke control areas have been "authorised" in Regulations and that
appliances used to burn solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order
made and signed by the Secretary of State or Minister in the devolved administrations. Further information on the
requirements of the Clean Air Act can be found here : http://smokecontrol.defra.gov.uk/Your local authority is
responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas
and you can contact them for details of Clean Air Act requirements "The Ecco Stoves 678EC2 has been
recommended as suitable for use in smoke control areas when burning wood logs with a maximum moisture
content of 20%"
Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom
T | +44 (0) 1527 857 814
SAVE THESE INSTRUCTIONS
TESTED TO EN15250 AND EN13240
E |
sales@eccostove.com
For all patents – See Addendum
678/03.05.23/V2
P a g e
W | www.eccostove.com
| 1 of 28

Advertisement

Table of Contents
loading

Summary of Contents for ECCO STOVE 678EC

  • Page 1 20%” Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 2 Netherlands: №: 2 213 945 (E) Russia: №: 2 213 945 (E Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 3 16. FUELS A) WOOD 17. RE-FUELLING 18. TAR DEPOSITS Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com For all patents – See Addendum...
  • Page 4 TOP SECTION. 27. ECCO STOVE WARRANTY 28. WARRANTY REGISTRATION 29. PAINTED STOVE NOTICE Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 5 The local authority will be able to inform you of the type of fuel you are allowed to burn in the area the stove is to be installed. Currently the Ecco stove is tested for wood burning but wood maybe burned in a smokeless designated zone provided it is operated to the following instructions (see Item 12).
  • Page 6: Flue Outlet

    The Ecco Stove has triple baffle system prior to exit of flue gasses to exhaust, to enable the maximum of heat to be extracted and utilised within the appliance and hence the air space within which the appliance is situated.
  • Page 7: Ash Grate

    (which does not smell as wood smoke wood, it has a factory smell associated with it). Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 8: Air Controls

    The Ecco Stove is produced from a self coloured material and as such variations in colour and texture of that material may be evident but adding to the uniqueness of the product, unless ordered as a pre- factory painted or as ready for paint on site finish to co-ordinate with home decor.
  • Page 9: Primary Air

    2) secondary air down the face of the glass and tertiary air through the same rear pre-drilled back boards. The combustion characteristics haven’t changed. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 10: Firing The Stove

    COMPONENTS FOR OUTSIDE AIR Model 678EC has an added air box mounted between the back panel and base section joint. 1 metre alloy tube with an insulation tube over and air vent to be fitted on the outside wall with spigot and 2 clamps are included.
  • Page 11 Never over fill the fire box, 1.2kgs or so of split logs is a typical full load. Running the stove above 200˚C constitutes over firing the stove and after which point damage may occur to the stove. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 12 Under firing warning If when re-firing; re-fuelling or lighting the Ecco stove, it must be fired up to 150°C or more for each new wood load for proper combustion – if allowed to “tick over” below this temperature tar build up will occur and subsequent blocking of the flue ways.
  • Page 13: Ash Removal

    Speak to your retailer for advice or fitting. The Ecco stove is equipped to accept an outside primary air facility which requires an extra tube extension and back box for installation.
  • Page 14 19. FLUE CONNECTION AND FLUE LININGS Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 15: Cleaning And Maintenance

    Silicon Carbide and may result in cracking around the flue which would not be covered under the guarantee. The nominal flue outlet of the Ecco Stove is 150 mm diameter for which a 150 mm flue liner insulated around within the masonry chimney with perlite grains or similar or rockwool wrap is strongly advised, or a suitably insulated pre-fabricated twin wall stainless steel flue system.
  • Page 16 (only carry out these works when the stove is not alight). The stove is now ready for re-use after all cleaning plugs have been re-fitted. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 17: Paint Finishes

    (Certain paints may discolour however) . 22. ASSEMBLY The Ecco Stove is delivered in 7 main structural parts: bottom section, grate section, left and right sides, back section, baffle brick and top section. Secondary points are two rear baffles (Vermiculite); vermiculite spacer blocks; one fixed front grate plug.
  • Page 18: Left Side

    This section to be stood firmly onto Part A using the locating pips Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom to position accurately. Ensure this section neatly holds the joint T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 19 This seal butts up to the door frame left and right. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 20 THE STOVE MAY NOW BE LIT MODEL 678EC TECHNICAL SLOW HEAT RELEASE APPLIANCE BS15250 a) Outputs: Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 21 (or the same room the Ecco Stove stands in) with a minimum angle of 45⁰ for natural convection. ducts off Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 22: Health And Safety

    The requirements of the Health and Safety At Work Act must be met when installing this stove. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 23 Should it be required this method of heating be continued a fresh fuelling may be undertaken and initial firing procedures followed Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 24 60mm max width with 2 logs laid across firebox and 2 logs laid atop, offset to fit firebox width as below- LOG LAYOUT 678EC MAXIMUM LOG LENGTH 300mm Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 25 Clearance Distance to Combustibles - Rear 350mm Clearance Distance to Combustibles - Side 450mm Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 26 678/03.05.23/V2 P a g e | 26 of 28 ECCO STOVE WARRANTY Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com W | www.eccostove.com...
  • Page 27 The Product = The Ecco Stove. 1. Please read your user instructions to ensure that you get the best from your Ecco Stove. Operating it properly is essential for this type of appliance to get the correct results. Always ask for help if you are unsure 2.
  • Page 28: Specifications

    Paint finishes will change colour with use. This warranty does not cover such changes. 8. Fuels The warranty only applies to the use of wood logs on your Ecco Stove. Coals or processed petro chemical fuels void the warranty as their use may produce blockage in flueways.
  • Page 29: Installation Details

    REAR: HEARTH PROJECTION IN FRONT OF STOVE: Upon completion of this form please send it to Ecco Stove Ltd, Foster House, 2 Redditch Road, Studley, B80 7AX, UK. Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom T | +44 (0) 1527 857 814 sales@eccostove.com...
  • Page 30 | 30 of 28 Painted finish note: As the Silicon Carbide masonry body of the Ecco Stove will absorb both temperature and moisture it is possible that in certain environments of high humidity or where condensation is present either in the surroundings or within the flue, it can cause paint to bubble or flake on the stoves outer body.

This manual is also suitable for:

E850