LG LP-F8081CL Service Manual page 37

Package air conditioner
Table of Contents

Advertisement

7.4 Gas Charging
1) Cooling mode
(After Evacuation)
Charging
cylinder
• Procedure
¤ Connect the charge hose to the charging cylinder.
• Connect the charge hose which you disconnected
from the vacuum pump to the valve at the bottom
of the cylinder.
• If you are using a gas cylinder, use a scale and
reverse the cylinder so that the system can be
charged with liquid.
¤ŁPurge the air from the charge hose.
• Open the valve at the bottom of the cylinder and
press the check valve on the charge set to purge
the air. (Be careful of the liquid refrigerant). The
procedure is the same if using a gas cylinder.
¤ØOpen the valve (Lo side) on the charge set and
charge the system with liquid refrigerant.
• If the system can not be charged with the
specified amount of refrigerant, it can be charged
with a little at a time (approximately 150g each
time) while operating the air conditioner in the
cooling cycle; however, one time is not sufficient,
wait approximately 1 minute and then repeat the
procedure (pumping down-pin).
Indoor unit
Check valve
Lo
OPEN
(1)
Liquid side
Open
3-Way
valve
Gas side
Open
3-Way
valve
CLOSE
This is different from previous procedures.
Because you are charging with liquid refrigerant
from the gas side, absolutely do not attempt to
charge with larger amounts of liquid refrigerant
while operating the air conditioner.
¤ŒImmediately disconnect the charge hose from the
3-way(gas side) valve's service port.
• Stopping partway will allow the gas to be
discharged.
• If the system has been charged with liquid
refrigerant while operating the air conditioner turn
off the air conditioner before disconnecting the
hose.
¤ºMount the valve stem nuts and the service port
nut.
• Use a torque wrench to tighten the service port nut.
• Be sure to check gas leakage.
–37–
Outdoor unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp-f8081hlLp-f8081zl

Table of Contents