MB Ordering Information for T5 and T8
S A M P L E N U M B E R : M B - 1 5 4 T 5 - F B - U N V- E B T 1- U
Blank=4' Length
8T=8' Tandem
Length
Series
MB= Micro-Bay
Number of Lamps
1=1 Lamp
2=2 Lamps
Lamp Types
32=32W T8 (48")
54T5=54W T5HO (48")
Reflector
FB=Focus Beam
TB=Task Beam (Medium)
NB=Normal Beam
NOTES:
(1)
Products also available in non-US voltages and frequencies for international
(2)
markets.
Voltage to be specified with emergency ballast option.
specified when ordered with plugs, motion or emergency ballasts.
(5)
with PI/CPI option. See below.
2 lamp ballast configurations only in UNC versions.
(6)
Not for use in high abuse applications such as gymnasiums.
(8)
separately.
For use with T5HO Focus, Normal or Wide Beam optics only.
available on select T8 ballast systems. Consult factory.
PI Ordering Information
Catalog
Circuit
Number
Number of
Wired To
Suffix
Circuits
Ballast
PI 1 BLK
1
Black
PI 2 BLU
2
Blue
PI 2 BLK
2
Black
PI 3 RED
3
Red
PI 3 BLU
3
Blue
PI 3 BLK
3
Black
P I 1 - S i n g l e C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 1 B L K - W G
PI1= Single
NG= No Ground (ground provided
Circuit
by fixture body)
WG= With Ground (separate
BLK=Black Hot
ground wire in harness)
P I 3 - T h r e e C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 3 B L K - W G
PI3= Three
Leave Blank=Single
Circuit
Neutral
2NEU=Two Neutrals
BLK=Black Hot
BLU=Blue Hot
RED=Red Hot
Leave Blank=Single
Neutral
For complete product data, reference the Fluorescent Specification binder. Specifications & dimen-
/WHT=White Neutral
sions subject to change without notice. Consult your Cooper Lighting Representative for availability
/GRY=Gray Neutral
and ordering information.
Voltage
Ballast Type
UNV=Universal
T5 Systems
120-277 Voltage
EBT =T5 Linear Electronic Program Rapid
UNC=Universal
Start. Total Harmonic Distortion < 10%
(9)
347/480 Voltage
No. of Ballast
1 or 2
Options
EHT =T5 Linear Electronic Program Rapid Start
GL=Single Element Fuse
High Ambient.
GM=Double Element Fuse
Total Harmonic Distortion < 10%
(2)
EL=Emergency Installed
No. of Ballast
1 or 2
DIM=Dimming
T8 Systems
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1 or 2
EB8 /PLUS= T8 Electronic Instant Start.
No. of
Ballast
(3)
Voltage must be
1 or 2
(4)
Cannot be combined
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
(7)
Must ship as accessory
(9)
UNC option
No. of Ballast
1 or 2
ER8 /PLUS= T8 Electronic Program Start.
No. of
Ballast
1 or 2
DIM=Dimming
Catalog Numbering System
The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the
sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:
PI-1 = One Circuit - 2 Wires: one black, one white
PI-2 = Two Circuits - 3 Wires: one black, one blue, one white
PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white
When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit.
Each circuit in fixture must be ordered as a separate line item, with a different hot wire color specified.
All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord
and cord & plug sets must be ordered separately if PI option is chosen.
NG= No Ground (ground provided
by fixture body)
WG= With Ground (separate
ground wire in harness)
(1)
Options
PI/CPI=Plug-In (1, 2 or 3)
Specify Circuit
(see PI Ordering Information Below)
(5)
C3=3' Power Cord
C6=6' Power Cord
PC3-=3' Power Cord & Plug
(Specify Voltage)
PC6-=6' Power Cord & Plug
(5)
(Specify Voltage)
Accessories (order separately)
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain
Sets w/S-Hooks
(9)
GRIPPLE-Y- =Y Mounting Toggle, #2 Cable
(5)
(Specify 10' or 30')
GRIPPLE-TOGGLE- =Single Toggle, #2 Cable
(Specify 10' or 30')
MB-EXT-LONG-CONN-KIT-U= Rigid Connector
Support for Continuous Channel Installation
(5)
MS=Aisle Coverage Motion Sensor
High Ballast Factor >1.15.
MSO=360˚ Coverage Motion Sensor
Total Harmonic Distortion < 10%
MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage
Motion Sensor , Center Mount Hardware,
120/277V
MB-SENSOR-KIT-END/MT-U=Aisle Coverage
Motion Sensor , End Mount Hardware,
120/277V
MB-SENSOR-KIT-CTR/480V-U=Aisle Coverage
Motion Sensor , Center Mount Hardware,
High Ballast Factor >1.15.
480V
Total Harmonic Distortion < 10%
MB-SENSOR-KIT-END/480V-U=Aisle Coverage
Motion Sensor, End Mount Hardware, 480V
WG/MB-4FT-T5-NB-B=Wireguard for T5HO
P I 2 - Tw o C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 2 B L K - W G
PI2= Two
Leave Blank=Single
Circuit
Neutral
2NEU=Two Neutrals
BLK=Black Hot
BLU=Blue Hot
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
Packaging
U=Unit Pack
(4)
(4)
(3), (4)
(3), (4)
(6)
(3), (7)
(3), (7)
(8)
NG= No Ground
(ground provided by
fixture body)
WG= With Ground
(separate ground wire
in harness)

Advertisement

loading

This manual is also suitable for:

Metalux micro-bay mb-132-nbMetalux micro-bay mb-154-nbMetalux micro-bay mb-232-fbMetalux micro-bay mb-254-fb