Omron NE-C303K-KDUK Instruction Manual page 2

Compressor nebulizer

Advertisement

Symbols description
Need for the user to
consult the instructions
Humidity limitation
for use
Applied part – Type BF
Degree of protection
Atmospheric pressure
against electric shock
limitation
(leakage current)
Class ll
Protection against
Power ON
electric shock
Ingress protection
IP XX
degree provided by
Power OFF
IEC 60529
CE Marking
Alternating current
LOT number
Medical Device
Serial number
Date of Manufacture
Temperature limitation
Product production date is integrated in the Serial number, which placed
on the product and/or sales package: the first 4 digits mean year of
production, the next 2 digits mean month of production.
General Notes:
• IP classification is degrees of protection provided by enclosures in
accordance with IEC 60529. The compressor is protected against solid
foreign objects of 12 mm diameter and greater such as a finger, and
against vertically falling water drops which may cause issues during a
normal operation.
• Subject to technical modification without prior notice.
• The device may not work if the temperature and voltage conditions are
different to those defined in the specifications.
• Performance may vary with drugs such as suspensions or high viscosity.
See drug supplier's data sheet for further details.
Troubleshooting
In case of any of the below problems occur during use, first check that no
other electrical device is within 30 cm. If the problem persists, please refer to
the table below.
The device does not switch on
• Check that the power plug is properly fitted to the power outlet.
• Make sure the power switch is in the on position (
).
The device switches on but does not nebulize
• Make sure the vaporizer head is fitted in the nebulizer kit.
• Make sure the air tube is not squashed or crooked.
• Check the air filter for blockage and dirt. Replace if necessary.
• Check that sufficient amount of medication has been put into the nebulizer kit.
The device suddenly stops working during operation.
• The thermal cut-out has shut the device down for one of the following reasons:
- the device was working in an environment with temperatures higher
than 40°C;
- the ventilation slots were covered.
Do not attempt to repair the device. Do not open and/or tamper with the
device. No parts of the device are user serviceable. Return the device to an
authorized OMRON retail outlet or distributor.
Please report to the manufacturer and the competent authority of the Member
State in which you are established about any serious incident that has
occurred in relation to this device.
Warranty
Thank you for buying an OMRON product. This product is constructed of
high quality materials and great care has been taken in its manufacturing.
It is designed to give you the highest level of comfort, provided it is properly
operated and maintained as described in the instruction manual. This product
is guaranteed by OMRON for a period of 3 years after the date of purchase.
The proper construction, workmanship and materials of this product is
guaranteed by OMRON. During this period of guarantee OMRON will,
without charge for labour or parts, repair or replace the defect product or any
defective parts. The guarantee does not cover any of the following:
a. Transport costs and risks of transport.
b. Costs for repairs and/or defects resulting from repairs done by
unauthorized persons.
c. Periodic check-ups and maintenance.
d. Failure or wear of optional parts or other attachments other than the main
device itself, unless explicitly guaranteed above.
e. Costs arising due to non-acceptance of a claim (those will be charged for).
f. Damages of any kind including personal caused accidentally or
from misuse.
Should guarantee service be required please apply to the dealer whom the
product was purchased from or an authorised OMRON distributor. For the
address refer to the product packaging / literature or to your specialised retailer.
Repair or replacement under the guarantee does not give rise to any
extension or renewal of the guarantee period.
The guarantee will be granted only if the complete product is returned
together with the original invoice / cash ticket issued to the consumer by the
retailer. OMRON reserves the right to refuse the guarantee service if any
unclear information has been given.
Optional Medical Accessories
Product Description
Model
Nebulizer Kit
NEB6024
Adult Mask (PVC)
NEB6007
Child Mask (PVC)
NEB6008
Mouthpiece
NEB6019
Adapter
NEB6015
Air Tube (PVC, 100 cm)
NEB6004
Nasal shower*
NEB6014
* Reduces nasal respiratory symptoms by cleaning a blocked nose.
Other Optional/Replacement Parts
Product Description
Model
Air Filter Set (Contents: 3 pieces)
3AC408
Important information regarding Electro Magnetic Compatibility (EMC)
This device manufactured by 3A HEALTH CARE S.r.l. conforms to
EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard.
Further documentation in accordance with this EMC standard is available
at OMRON HEALTHCARE EUROPE at the address mentioned in this
instruction manual or at www.omron-healthcare.com.
DISPOSAL PROCEDURE (Dir. 2012/19/EU-WEEE)
This product is not to be treated as regular household waste but must
be returned to a collection point for recycling electric and electronic
devices. Further information is available from your municipality, your
municipality's waste disposal services, or the retailer where you
purchased your product.
Manufacturer
3A HEALTH CARE S.r.l.
Via Marziale Cerutti, 90F/G
25017 Lonato del Garda (BS)
Italy
Distributor
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp,
THE NETHERLANDS
www.omron-healthcare.com
Subsidiary
Importer in
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes,
the United
MK15 0DG, UK
Kingdom
www.omron-healthcare.com
and UK
responsible
person