  • Page 1 DS-K3B530X Series Swing Barrier User Manual...
  • Page 2 WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,...
  • Page 3 During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method;...
  • Page 4 DS-K3B530X Series Swing Barrier User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 5 DS-K3B530X Series Swing Barrier User Manual under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
  • Page 6 DS-K3B530X Series Swing Barrier User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death.
  • Page 7 DS-K3B530X Series Swing Barrier User Manual Cautions: Stainless steel may be corroded in some circumstances. You need to clean and care the device by ● using the stainless steel cleaner. It is suggested to clean the device every month. Do not drop the device or subject it to physical shock, and do not expose it to high ●...
  • Page 8 DS-K3B530X Series Swing Barrier User Manual Available Models Product Name Model Description Swing Barrier DS-K3B530LX-L/DS-K3B530X-L/ Left Pedestal DS-K3B530LX-M/DS-K3B530X- Middle Pedestal DS-K3B530LX-R/DS-K3B530X-R Right Pedestal...
  • Page 9: Table Of Contents

    DS-K3B530X Series Swing Barrier User Manual Contents Chapter 1 Overview ........................1 1.1 Introduction ........................... 1 1.2 Main Features ........................1 1.3 Light Description ........................2 Chapter 2 System Wiring ......................4 Chapter 3 Install Pedestals ......................7 Chapter 4 General Wiring ......................12 4.1 Components Introduction ....................
  • Page 10 DS-K3B530X Series Swing Barrier User Manual 4.4.1 Configuration via Button ..................... 30 4.4.2 Study Mode Settings ....................33 4.4.3 Keyfob Pairing ......................35 4.4.4 Initialize Device ......................37 Chapter 5 Activation ......................... 38 5.1 Activate via Web Browser ....................38 5.2 Activate via Mobile Web ......................
  • Page 11 DS-K3B530X Series Swing Barrier User Manual 6.5.14 Prompt Schedule ....................... 64 6.5.15 Upgrade and Maintenance ..................66 6.5.16 Device Debugging ..................... 67 6.5.17 Component Status ....................68 6.5.18 Log Query ........................69 6.5.19 Certificate Management ................... 69 Chapter 7 Configure the Device via the Mobile Browser ............71 7.1 Login ............................
  • Page 12 DS-K3B530X Series Swing Barrier User Manual 8.3.1 Add Group ........................97 8.3.2 Import Resources to Group ..................97 8.4 Person Management ......................98 8.4.1 Add Organization ......................98 8.4.2 Import and Export Person Identify Information ............99 8.4.3 Get Person Information from Access Control Device ..........101 8.4.4 Issue Cards to Persons in Batch .................
  • Page 13: Chapter 1 Overview

    DS-K3B530X Series Swing Barrier User Manual Chapter 1 Overview 1.1 Introduction The Swing barrier with 14 IR lights is designed to detect unauthorized entrance or exit. By adopting the swing barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc.
  • Page 14: Light Description

    DS-K3B530X Series Swing Barrier User Manual System will cancel the passing permission if a person does not pass through the lane within the valid passing duration. Bidirectional (Entrance/Exit) lane ● The barrier opening and closing speed can be configured according to the visitor flow.
  • Page 15 DS-K3B530X Series Swing Barrier User Manual Note Light stays blue: inductive/remain open ● Light stays white: controlled/barrier free ● Light stays red: remain closed ● Barrier Light The barrier light stays white by default. You can set the barrier light color at your needs.
  • Page 16: Chapter 2 System Wiring

    DS-K3B530X Series Swing Barrier User Manual Chapter 2 System Wiring The preparation before installation and general wiring. Steps Note The device should be installed concrete surface or other flat non-flammable surface. ● If the installation area is too close to the wall, make sure the distance between the pedestal and ●...
  • Page 17 DS-K3B530X Series Swing Barrier User Manual Figure 2-1 Dimension 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L + 272 mm. L represents the lane width.
  • Page 18 DS-K3B530X Series Swing Barrier User Manual Figure 2-2 Hole Position and System Wiring 4. Bury cables. Each lane buries 1 high voltage cable and 1 low voltage cable. For details, see the system wiring diagram of step 3. Note High voltage: AC power input ●...
  • Page 19: Chapter 3 Install Pedestals

    DS-K3B530X Series Swing Barrier User Manual Chapter 3 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note The device should be installed on the concrete surface or other flat non-flammable surfaces.
  • Page 20 DS-K3B530X Series Swing Barrier User Manual Figure 3-1 Remove Side Panel Screws 3. Remove the side panels and move the pedestals to the corresponded positions according to the entrance and exit marks on the pedestals.
  • Page 21 DS-K3B530X Series Swing Barrier User Manual Figure 3-2 Remove Side Panel Screws Note For detailed information about system wiring, see System Wiring . 4. Secure the pedestals with expansion bolts and fix the side panels to its original position with screws.
  • Page 22 DS-K3B530X Series Swing Barrier User Manual...
  • Page 23 DS-K3B530X Series Swing Barrier User Manual Figure 3-3 Remove Maintenance Door Note For detailed information about cables, see General Wiring .
  • Page 24: Chapter 4 General Wiring

    DS-K3B530X Series Swing Barrier User Manual Chapter 4 General Wiring Note When you should maintain or disassemble the high voltage modules, you should remove the ● entire high voltage modules and maintain it outside the turnstile. You should unplug the cables that connected to the peripherals before maintenance to avoid destroy of the device.
  • Page 25 DS-K3B530X Series Swing Barrier User Manual Figure 4-1 Serial Port The picture displayed below describes the IR sending/receiving module and their corresponding number on the pedestal.
  • Page 26: Wiring

    DS-K3B530X Series Swing Barrier User Manual Figure 4-2 IR Sending/Receiving Module Position Note Standing at the entrance position in the lane, the IR modules on your left are the IR sending modules, the ones on your right are the IR receiving modules.
  • Page 27: Terminal Description

    DS-K3B530X Series Swing Barrier User Manual 4.3 Terminal Description 4.3.1 Main Lane Control Board Terminal Description The main lane control board contains interconnecting interface, access control board interface, fire input interface, exit button interface, 12 VDC output interface, 24 VDC input interface, fan interface, communication interface, encoder interface, power supply interface for motor, supercapacitor interface, main brake interface, adaptor interface and tamper interface.
  • Page 28: Sub Lane Control Board Terminal Description

    DS-K3B530X Series Swing Barrier User Manual Figure 4-3 Main Lane Control Board Terminals 4.3.2 Sub Lane Control Board Terminal Description The sub lane control board contains interconnecting interface, BUS interface, exit button interface, 12 VDC output interface, 24 VDC input interface, fan interface, communication interface, encoder interface, power supply interface for motor, supercapacitor interface, sub brake interface, adaptor interface and tamper interface.
  • Page 29: Access Control Board Terminal Description (Optional)

    DS-K3B530X Series Swing Barrier User Manual Figure 4-4 Sub Lane Control Board Terminals 4.3.3 Access Control Board Terminal Description (Optional) Access control board is mainly used for authority identification in places with high security levels such as public security or judicial place, external device accessing, and communication with the...
  • Page 30 DS-K3B530X Series Swing Barrier User Manual Figure 4-5 Access Control Board Note RS-485A corresponds to UART 5 on web and is for QR code scanner connection at entrance by ● default; RS-485C corresponds to UART 7 on web and is for card reader connection at entrance by default.
  • Page 31: Main Extended Interface Board Terminal Description

    DS-K3B530X Series Swing Barrier User Manual Figure 4-6 Wring Diagram of BUS3 Interface Note RS-232A corresponds to UART 1 on web. 4.3.4 Main Extended Interface Board Terminal Description The main extended interface board contains the sub-1G antenna interface, barrier light interface, loudspeaker interface, debugging port, Wiegand/exit button interface, 5 VDC output and communication interface.
  • Page 32 DS-K3B530X Series Swing Barrier User Manual Figure 4-7 Main Optional Board Terminal Note When the device is installed with access control board, the loudspeaker shall be connected to the access control board. If not, the loudspeaker shall be connected to the main extended interface...
  • Page 33: Sub Extended Interface Board Terminal Description

    DS-K3B530X Series Swing Barrier User Manual 4.3.5 Sub Extended Interface Board Terminal Description Figure 4-8 Sub Extended Interface Board Note RS-485B corresponds to UART 6 on web and is for QR code scanner connection at exit by default. ● RS-485D corresponds to UART 4 on web and is for card reader connection at exit by default.
  • Page 34: Lane Status Indicator Board

    DS-K3B530X Series Swing Barrier User Manual Figure 4-9 Card Reader Board 4.3.7 Lane Status Indicator Board For details about lane status indicator position, see Light Description . Lane status indicator board in different pedestals are shown as follows. Table 4-1 Lane Status Indicator Board...
  • Page 35: Nfc Board Terminal Description (Optional)

    DS-K3B530X Series Swing Barrier User Manual 4.3.8 NFC Board Terminal Description (Optional) The NFC board is shown as follows. Figure 4-10 NFC Board Note The NFC board is connected to the main lane control board at the entrance only. NFC function description: If device hotspot is disabled, make sure your mobile phone and the device are connected to the ●...
  • Page 36: Ir Adapter Board Terminal Description (Optional)

    DS-K3B530X Series Swing Barrier User Manual 4.3.10 IR Adapter Board Terminal Description (Optional) Figure 4-12 IR Adapter Board Note The main lane IR adapter board should be connected to the IR adapter terminal 1 of the main ● lane control board.
  • Page 37: Wiring

    DS-K3B530X Series Swing Barrier User Manual Figure 4-13 General Wiring Note The power cable from power supply to the main lane control board has been connected. You will ● need to prepare the 14AWG power cable to connect the AC power input to power supply.
  • Page 38: Wiring

    DS-K3B530X Series Swing Barrier User Manual Note There are 2 RS-485 interfaces on the access control board for entrance. Refer to Access Control ● Board Terminal Description (Optional) for details. There are 2 RS-485 interfaces on the sub extended interface board for exit. Refer to Sub Extended Interface Board Terminal Description for details.
  • Page 39: Alarm Input Wiring

    DS-K3B530X Series Swing Barrier User Manual 4.3.14 Alarm Input Wiring On the main lane control board, you can wire the fire alarm input interface. Figure 4-16 Remaining Open Figure 4-17 Remaining Closed 4.3.15 Exit Button Wiring The main and sub lane control board each has 1 button interface, which can be connected to exit...
  • Page 40: Device Settings Via Button

    DS-K3B530X Series Swing Barrier User Manual Figure 4-18 Exit Button Wiring Note The face recognition devices are powered via 12 VDC power output interface of the main and ● sub lane control board. Barrier open at the entrance: connect to BTN1 and GND.
  • Page 41 DS-K3B530X Series Swing Barrier User Manual Function Main Lane Control Board & Main Lane Control Board & Loudspeaker (Connected to Access Control Board & Main Extended Interface Loudspeaker (Connected to Board) Access Control Board) Memory Mode Configure via button Configure via button/​ w eb...
  • Page 42: Configuration Via Button

    DS-K3B530X Series Swing Barrier User Manual Function Main Lane Control Board & Main Lane Control Board & Loudspeaker (Connected to Access Control Board & Main Extended Interface Loudspeaker (Connected to Board) Access Control Board) Climbing over Barrier Enable or disable via button...
  • Page 43 DS-K3B530X Series Swing Barrier User Manual Button Description Figure 4-19 Button Exit Button Press to open the barrier from the entrance position. ● Double press to open the barrier from the exit position. ● Parameter Configuration Button LEFT: Press to add 10 to configuration data.
  • Page 44 DS-K3B530X Series Swing Barrier User Manual Figure 4-20 Procedure Steps: 1. Hold OK button for 3 s until one beep occurs. The device enter the configuration mode. Level 1 menu lights up. The display screen displays the configuration No. 1.
  • Page 45: Study Mode Settings

    DS-K3B530X Series Swing Barrier User Manual Note - The configuration No. will display in a cycle. - Each configuration No. refers to a function. For details about the configuration No. and its related function, see Button Configuration Description . 4.4.2 Study Mode Settings Set the closed position of the device barrier.
  • Page 46 DS-K3B530X Series Swing Barrier User Manual Figure 4-21 DIP Switch Location Figure 4-22 Study Mode 2. Adjust the closed position of the barrier. 3. Power on the device. The device will remember the current position (closed position) automatically. 4. Power off the device.
  • Page 47: Keyfob Pairing

    DS-K3B530X Series Swing Barrier User Manual Figure 4-23 Normal Mode 6. Power on the device again. Note For details about the DIP switch value and meaning, see DIP Switch Description. The barrier will open automatically and turns back to the closed position. At this circumstance, the device enters the normal mode.
  • Page 48 DS-K3B530X Series Swing Barrier User Manual 3. Exit the keyfob pairing mode. 1) Enter the configuration mode. 2) Set the configuration No. in Level-1 to 2. The device will enter the keyfob pairing mode. 3) Set the configuration No. in the Level-2 menu to 1. The device will exit the keyfob pairing mode.
  • Page 49: Initialize Device

    DS-K3B530X Series Swing Barrier User Manual Figure 4-25 Enable Keyfob Paring Mode 3. Power on the turnstile and it will enter the keyfob pairing mode. 4. Hold the Close button for more than 10 seconds. The keyfob's indicator of the will flash twice if the pairing is completed.
  • Page 50: Chapter 5 Activation

    DS-K3B530X Series Swing Barrier User Manual Chapter 5 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported.
  • Page 51: Activate Via Sadp

    Get the SADP software from the supplied disk or the official website http:// ● www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet.
  • Page 52: Activate Device Via Ivms-4200 Client Software

    DS-K3B530X Series Swing Barrier User Manual Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product.
  • Page 53 DS-K3B530X Series Swing Barrier User Manual Steps Note This function should be supported by the device. 1. Enter the Device Management page. 2. Click on the right of Device Management and select Device. 3. Click Online Device to show the online device area.
  • Page 54: Chapter 6 Operation Via Web Browser

    DS-K3B530X Series Swing Barrier User Manual Chapter 6 Operation via Web Browser 6.1 Login You can login via the web browser or the remote configuration of the client software. Note Make sure the device is activated. For detailed information about activation, see Activation .
  • Page 55: Person Management

    DS-K3B530X Series Swing Barrier User Manual You can check if the device is working properly. Click View More to view the detailed component status. Remote Control The door is opened/closed/remaining open/remaining closed. Real-Time Event You can view the event Employee ID, Name, Card No., Event Type, Time, and Operation. You can also click View More to enter the search conditions, including the event type, employee ID, the name, the card No., the start time, and the end time, and click Search.
  • Page 56 DS-K3B530X Series Swing Barrier User Manual Figure 6-2 Add Person Add Basic Information Click Person Management → Add to enter the Add Person page. Add the person's basic information, including the employee ID, the person's name, the gender, and person type.
  • Page 57: Search Event

    DS-K3B530X Series Swing Barrier User Manual Enable Long-Term Effective User, or set Validity Period and the person can only has the permission within the configured time period according to your actual needs. Click Save to save the settings. Add Card Click Person Management →...
  • Page 58 DS-K3B530X Series Swing Barrier User Manual Figure 6-3 Search Event Enter the search conditions, including the event type, the employee ID, the name, the card No., the start time, and the end time, and click Search. The event types contain access control event and ID card event. If you choose to search for ID card event, you will not need to enter the employee ID, the name, or the card No.
  • Page 59: Configuration

    DS-K3B530X Series Swing Barrier User Manual 6.5 Configuration 6.5.1 View Device Information Click Configuration → System → System Settings → Basic Information to enter the configuration page. You can view the device name, language, model, serial No., version, IO input, IO output, and local RS-485 number.
  • Page 60: Set Dst

    DS-K3B530X Series Swing Barrier User Manual You should set the NTP server's IP address, port No., and interval. Manual By default, the device time should be synchronized manually. You can set the device time manually or check Sync. with Computer Time to synchronize the device time with the computer's time.
  • Page 61: View Device Arming/Disarming Information

    DS-K3B530X Series Swing Barrier User Manual Go to Configuration → System → User Management → Online Users to view the list of online users. 6.5.6 View Device Arming/Disarming Information View device arming type and arming IP address. Go to Configuration → User Management → Arming/Disarming Information .
  • Page 62 DS-K3B530X Series Swing Barrier User Manual If you check the function, the system will allocate the IPv4 address, IPv4 subnet mask, the IPv4 default gateway automatically. DNS Server Set the preferred DNS server and the Alternate DNS server according to your actual need.
  • Page 63 DS-K3B530X Series Swing Barrier User Manual Figure 6-6 Network Service HTTP It refers to the port through which the browser accesses the device. For example, when the HTTP Port is modified to 81, you need to enter http://192.0.0.65:81 in the browser for login.
  • Page 64: Set Audio Parameters

    DS-K3B530X Series Swing Barrier User Manual 6.5.8 Set Audio Parameters Set the image quality, resolution, and the device volume. Set Audio Parameters Click Configuration → Video/Audio → Audio . Figure 6-7 Set Audio Parameters Drag the block to adjust the output volume.
  • Page 65 DS-K3B530X Series Swing Barrier User Manual Figure 6-8 Event Linkage 2. Set event source. - If you choose Linkage Type as Event Linkage, you need to select event types from the drop- down list. - If you choose Linkage Type as Card Linkage, you need to enter the card No. and select the...
  • Page 66: Access Control Settings

    DS-K3B530X Series Swing Barrier User Manual - If you choose Linkage Type as Employee ID Linkage, you need to enter the employee ID and select the card reader. 3. Set linked action. Linked Buzzer Enable Linked Buzzer and select Start Buzzing or Stop Buzzing for the target event.
  • Page 67 DS-K3B530X Series Swing Barrier User Manual Figure 6-9 Set Authentication Parameters Click Save to save the settings after the configuration. Terminal Choose Entrance or Exit for settings. Terminal Type/Terminal Model Get terminal description. They are read-only. Enable Authentication Device Enable the authentication function.
  • Page 68 DS-K3B530X Series Swing Barrier User Manual When the access control device cannot connect with the card reader for longer than the set time, the card reader will turn offline automatically. Note The authentication interval value ranges from 2 s to 255 s.
  • Page 69 DS-K3B530X Series Swing Barrier User Manual Set the door open duration when first person is in. After the first person is authorized, it allows multiple persons access the door or other authentication actions. Note The duration ranges from 1 s to 1440 s.
  • Page 70 DS-K3B530X Series Swing Barrier User Manual Steps Note Some device models do not support this function. Refer to the actual products when configuration. 1. Click Configuration → Access Control → Wiegand Settings . 2. Select Entrance or Exit. 3. Enable Wiegand function.
  • Page 71: Turnstile

    DS-K3B530X Series Swing Barrier User Manual Figure 6-12 Terminal Parameters 2. Set the device working mode. Permission Free Mode The device will not verify the person's permission, but only the person's validity period. If the person is in the validity period, the barrier will open.
  • Page 72 DS-K3B530X Series Swing Barrier User Manual Steps 1. Click Configuration → Turnstile → Basic Settings to enter the page. 2. View the Device Type, Device Model and Working Status. 3. Set Barrier Material, Lane Width, Barrier Height, Barrier Opening Speed and Barrier Closing Speed.
  • Page 73 DS-K3B530X Series Swing Barrier User Manual 4. Optional: Select a keyfob and click Delete to delete the keyfob. 5. Click Save. IR Detector Set IR detector. Steps 1. Click Configuration → Turnstile → IR Detector to enter the page. Figure 6-14 IR Detector 2.
  • Page 74 DS-K3B530X Series Swing Barrier User Manual Figure 6-15 People Counting 2. Check to enable People Counting. 3. Enable Device Offline People Counting at your actual needs. 4. Select People Counting Type as Invalid, Passing Detection or Authentication Number. 5. Optional: Click clear to clear all the people counting information.
  • Page 75: Card Settings

    DS-K3B530X Series Swing Barrier User Manual Note The alarm output duration ranges from 0 s to 3599 s. 3. Set Temperature Unit. 4. Check to enable Do Not Open Barrier When Lane is Not Clear. 5. Drag the block or enter the value to adjust the light board brightness.
  • Page 76: Set Privacy Parameters

    DS-K3B530X Series Swing Barrier User Manual M1 card encryption can improve the security level of authentication. Enable the function and set the encryption sector. By default, Sector 13 is encrypted. It is recommended to encrypt sector 13. Enable EM Card Enable EM card and authenticating by presenting EM card is available.
  • Page 77 DS-K3B530X Series Swing Barrier User Manual Figure 6-16 Customize Audio Content 2. Select time schedule. 3. Enable the function. 4. Set the appellation. 5. Set the time period when authentication succeeded. 1) Click Add Time Duration. 2) Set the time duration.
  • Page 78: Upgrade And Maintenance

    DS-K3B530X Series Swing Barrier User Manual Note If authentication is succeeded in the configured time duration, the device will broadcast the configured content. 3) Set the audio content. If you choose TTS, you need to set the language and enter the prompt content of authentication success.
  • Page 79: Device Debugging

    DS-K3B530X Series Swing Barrier User Manual Reboot Device Click Maintenance and Security → Maintenance → Restart . Click Restart to reboot the device. Upgrade Click Maintenance and Security → Maintenance → Upgrade . Select an upgrade type from the drop-down list. Click and select the upgrade file from your local PC.
  • Page 80: Component Status

    DS-K3B530X Series Swing Barrier User Manual To raise network security, disable SSH service. The configuration is only used to debug the device for the professionals. Print Log You can click Export to export log. 6.5.17 Component Status You can view the main lane and sub lane status.
  • Page 81: Log Query

    DS-K3B530X Series Swing Barrier User Manual Other Status You can view the status of the barrier and the keyfob receiving module. 6.5.18 Log Query You can search and view the device logs. Go to Maintenance and Security → Maintenance → Log .
  • Page 82 DS-K3B530X Series Swing Barrier User Manual Install Other Authorized Certificate If you already has an authorized certificate (not created by the device), you can import it to the device directly. Steps 1. Go to Maintenance and Security → Security → Certificate Management .
  • Page 83: Chapter 7 Configure The Device Via The Mobile Browser

    DS-K3B530X Series Swing Barrier User Manual Chapter 7 Configure the Device via the Mobile Browser 7.1 Login You can log in via mobile browser. Note Make sure the device is activated. You can log in via the following methods: If device hotspot is disabled, make sure your mobile phone and the device are connected to the ●...
  • Page 84: Configuration

    DS-K3B530X Series Swing Barrier User Manual Figure 7-1 Shortcut Entry and Network Status You can tap to fast enter the basic settings page, user page, keyfob page, light page and network page. 7.3 Configuration 7.3.1 Turnstile Basic Parameters You can set the basic parameters of the turnstile.
  • Page 85: User Management

    DS-K3B530X Series Swing Barrier User Manual Figure 7-2 Turnstile Basic Parameters Set Lane Width, Barrier Height, Barrier Height, Barrier Opening Speed and Barrier Closing Speed. Set the regular passing mode for the entrance and exit. Tap Save. 7.3.2 User Management...
  • Page 86 DS-K3B530X Series Swing Barrier User Manual Steps 1. Tap User to enter the settings page. Figure 7-3 Add User...
  • Page 87: Keyfob Settings

    DS-K3B530X Series Swing Barrier User Manual 2. Add user. 1) Tap 2) Set the following parameters. Employee ID Enter the employee ID. The Employee ID cannot be 0 or exceed 32 characters. It can be a combination of uppercase, lowercase letters and numbers.
  • Page 88: Light Settings

    DS-K3B530X Series Swing Barrier User Manual Figure 7-4 Keyfob Settings Set Working Mode as One-to-One or One-to-Many. Tap Management to enter the page. Tap + to add keyfob. Set keyfob name, serial No. and remain open permission. 7.3.4 Light Settings...
  • Page 89 DS-K3B530X Series Swing Barrier User Manual Lane Status Indicator Figure 7-5 Lane Status Indicator Settings Light Brightness is set Manual by default. Enter the value to adjust the light brightness manually. Set light color for inductive/remain open, remain closed and controlled/barrier-free mode...
  • Page 90: Network Settings

    DS-K3B530X Series Swing Barrier User Manual Barrier Light Figure 7-6 Barrier Light Settings Tap to enable Light on When on Standby at your actual needs and set the barrier light color. 7.3.5 Network Settings You can set the wired network, device hotspot and port.
  • Page 91 DS-K3B530X Series Swing Barrier User Manual Wired Network Set wired network. Tap Configuration → Communication Settings → Wired Network to enter the configuration page. Figure 7-7 Wired Network DHCP If you disable the function, you should set the IPv4 address, IPv4 subnet mask, and IPv4 default...
  • Page 92 DS-K3B530X Series Swing Barrier User Manual If you enable the function, the system will allocate the IPv4 address, IPv4 subnet mask, and IPv4 default gateway automatically. DNS Server Set the preferred DNS server and the Alternate DNS server according to your actual need.
  • Page 93 DS-K3B530X Series Swing Barrier User Manual Figure 7-8 Device Hotspot Tap to Enable Device Hotspot. Set hotspot Name and Password. Click Save. Serial Port Configuration Set serial port. Tap Configuration → Communication Settings → Serial Port Configuration to enter the...
  • Page 94: Device Basic Settings

    DS-K3B530X Series Swing Barrier User Manual Figure 7-9 Serial Port Configuration Select the port No., and set Baud Rate, Data Bit, Stop Bit and Parity. Set the Peripheral Type as Card Reader, Card Receiver, QR Code Scanner or Disable. Tap Save.
  • Page 95 DS-K3B530X Series Swing Barrier User Manual Tap Configuration → Basic Settings to enter the configuration page. Figure 7-10 Basic Configuration Language The language is set English by default. Voice Settings Tap to Enable Voice Prompt, select entrance or exit to set voice prompt and drag to set the volume.
  • Page 96: Access Control Settings

    DS-K3B530X Series Swing Barrier User Manual Tap to select the time zone and the device time. Tap DST to enter the DST setting page. Enable DST and set the DST start time, end time and bias time 7.3.7 Access Control Settings Set Door Parameters Tap Configuration →...
  • Page 97 DS-K3B530X Series Swing Barrier User Manual Door No. Select the device corresponded door No. Name You can create a name for the door. Open Duration Set the door unlocking duration. If the door is not opened for the set time, the door will be locked.
  • Page 98 DS-K3B530X Series Swing Barrier User Manual Figure 7-12 Authentication Settings 2. Tap Save. Terminal Choose Entrance or Exit for settings. Terminal Model Terminal model is read-only. Enable Authentication Device Enable the authentication function.
  • Page 99 DS-K3B530X Series Swing Barrier User Manual Authentication Authentication via card by default. Authentication Interval You can set the authentication interval of the same person when authenticating. The same person can only authenticate once in the configured interval. A second authentication will be failed.
  • Page 100 DS-K3B530X Series Swing Barrier User Manual Figure 7-13 Card Security Set the parameters and click Save. Enable NFC Card In order to prevent the mobile phone from getting the data of the access control, you can disable NFC card to increase the security level of the data.
  • Page 101 DS-K3B530X Series Swing Barrier User Manual M1 card encryption can improve the security level of authentication. Sector Enable the function and set the encryption sector. By default, Sector 13 is encrypted. It is recommended to encrypt sector 13. Enable EM Card Enable EM card and authenticating by presenting EM card is available.
  • Page 102 DS-K3B530X Series Swing Barrier User Manual Figure 7-14 Terminal Parameters Permission Free Mode The device will not verify the person's permission, but only the person's validity period. If the person is in the validity period, the barrier will open. You can enable Verify Credential Locally. After enabling the function, the device will only verify the person's permission without the schedule template, etc.
  • Page 103: View Device Information

    DS-K3B530X Series Swing Barrier User Manual Remote Authentication The device will upload the person's authentication information to the platform. The platform will judge to open the barrier or not. Verify Credential Locally The device will only verify the person's permission without the schedule template, etc.
  • Page 104: Chapter 8 Client Software Configuration

    DS-K3B530X Series Swing Barrier User Manual Chapter 8 Client Software Configuration You can call the hotline to get the iVMS-4200 client software installation package. 8.1 Configuration Flow of Client Software Follow the flow diagram below to configure on the client software.
  • Page 105: Device Management

    DS-K3B530X Series Swing Barrier User Manual 8.2 Device Management The client supports managing access control devices and video intercom devices. Example You can control entrance & exit and manage attendance after adding access control devices to the client; you can perform video intercom with the indoor stations and door stations.
  • Page 106 DS-K3B530X Series Swing Barrier User Manual Enter the device password. Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 107: Reset Device Password

    DS-K3B530X Series Swing Barrier User Manual 5. Open the exported template file and enter the required information of the devices to be added on the corresponding column. Note For detailed description of the required fields, refer to the introductions in the template.
  • Page 108: Manage Added Devices

    DS-K3B530X Series Swing Barrier User Manual All the online devices sharing the same subnet will be displayed in the list. 3. Select the device from the list and click on the Operation column. 4. Reset the device password. - Click Generate to pop up the QR Code window and click Download to save the QR code to your PC.
  • Page 109: Group Management

    DS-K3B530X Series Swing Barrier User Manual View Online User Click to view the details of online user who access the device, including user name, user type, IP address and login time. Refresh Device Click to refresh and get the latest device information.
  • Page 110: Person Management

    DS-K3B530X Series Swing Barrier User Manual 2. Click Device Management → Group to enter the group management page. 3. Select a group from the group list and select the resource type as Access Point, Alarm Input, Alarm Output, etc. 4. Click Import.
  • Page 111: Import And Export Person Identify Information

    DS-K3B530X Series Swing Barrier User Manual 8.4.2 Import and Export Person Identify Information You can import the information and pictures of multiple persons to the client software in a batch. Meanwhile, you can also export the person information and pictures and save them in your PC.
  • Page 112 DS-K3B530X Series Swing Barrier User Manual 2. Select an added organization in the list, or click Add in the upper-left corner to add an organization and then select it. 3. Click Import to open the Import panel and check Face.
  • Page 113: Get Person Information From Access Control Device

    DS-K3B530X Series Swing Barrier User Manual Before You Start Make sure you have added persons and their face pictures to an organization. ● Make sure you have enabled the Export Person Information function to display the Export ● button. See for details.
  • Page 114: Issue Cards To Persons In Batch

    DS-K3B530X Series Swing Barrier User Manual Note If you select the enrollment station, you should click Login, and enter IP address, port No., user name and password of the device. 5. Select the Getting Mode. Note The getting mode varies according to different devices. The access control device supports getting the person information by employee ID.
  • Page 115: Set Card Issuing Parameters

    DS-K3B530X Series Swing Barrier User Manual Steps 1. Enter Person module. 2. Select the person you want to report card loss for and click Edit to open the Edit Person window. 3. In the Credential → Card panel, click on the added card to set this card as lost card.
  • Page 116: Configure Schedule And Template

    DS-K3B530X Series Swing Barrier User Manual Enable or disable the buzzing when the card number is read successfully. Card No. Type Select the type of the card number according to actual needs. M1 Card Encryption This field is only available when the model is DS-K1F100-D8, DS-K1F100-D8E, or DS-K1F180-D8E.
  • Page 117: Add Template

    DS-K3B530X Series Swing Barrier User Manual 2) Drag the cursor to draw the time duration, which means in that duration of time, the configured access group is activated. Note Up to 8 time durations can be set to one holiday period.
  • Page 118: Set Access Group To Assign Access Authorization To Persons

    DS-K3B530X Series Swing Barrier User Manual 1) Click Week Schedule tab on the lower panel. 2) Select a day of the week and draw time duration(s) on the timeline bar. Note Up to 8 time duration(s) can be set for each day in the week schedule.
  • Page 119 DS-K3B530X Series Swing Barrier User Manual picture, linkage between card number and fingerprint, linkage between card number and fingerprint, card password, card effective period, etc). 1. Click Access Control → Authorization → Access Group to enter the Access Group interface.
  • Page 120: Configure Advanced Functions

    DS-K3B530X Series Swing Barrier User Manual 3) Click Apply All to Devices or Apply Changes to Devices. Apply All to Devices This operation will clear all the existed access groups of the selected devices and then apply the new access group to the device.
  • Page 121: Configure Device Parameters

    DS-K3B530X Series Swing Barrier User Manual Note For the card related functions(the type of access control card/multi-factor authentication), only ● the card(s) with access group applied will be listed when adding cards. The advanced functions should be supported by the device.
  • Page 122 DS-K3B530X Series Swing Barrier User Manual Display the card information when authenticating. Display Person Information Display the person information when authenticating. Overlay Person Info. on Picture Display the person information on the captured picture. Voice Prompt If you enable this function, the voice prompt is enabled in the device. You can hear the voice prompt when operating in the device.
  • Page 123 DS-K3B530X Series Swing Barrier User Manual 3. Select a door or floor to show its parameters on the right page. 4. Edit the door or floor parameters. Note The displayed parameters may vary for different access control devices. ● Some of the following parameters are not listed in the Basic Information page, click More to ●...
  • Page 124 DS-K3B530X Series Swing Barrier User Manual Note The duress code, super code, and dismiss code should be different. ● The duress code, super password, and the dismiss code should be different from the ● authentication password. The length of duress code, super password, and the dismiss code is according the device, ●...
  • Page 125 DS-K3B530X Series Swing Barrier User Manual When you inputting the password on the card reader, if the interval between pressing two digits is larger than the set value, the digits you pressed before will be cleared automatically. Alarm of Max. Failed Attempts Enable to report alarm when the card reading attempts reach the set value.
  • Page 126 DS-K3B530X Series Swing Barrier User Manual Set the matching security level when authenticating via 1:N matching mode. The larger the value, the smaller the false accept rate and the larger the false rejection rate when authentication. Live Face Detection Enable or disable the live face detection function. If enabling the function, the device can recognize whether the person is a live one or not.
  • Page 127 DS-K3B530X Series Swing Barrier User Manual Alarm Output Active Time How long the alarm output will last after triggered. 4. Click OK. 5. Optional: Set the switch on the upper right corner to ON to trigger the alarm output. Configure Parameters for Lane Controller After adding the lane controller to the client, you can configure its parameters for passing through the lane.
  • Page 128: Configure Other Parameters

    DS-K3B530X Series Swing Barrier User Manual Temperature Unit Select the temperature unit that displayed in the device status. 4. Click OK. 8.7.2 Configure Other Parameters After adding the access control device, you can set its parameters such as network parameters, capture parameters, RS-485 parameters, Wiegand parameters, etc.
  • Page 129 DS-K3B530X Series Swing Barrier User Manual Save Authenticating Face Picture If enabled, the captured face picture when authenticating will be saved on the device. MCU Version View the device MCU version. 5. Click Save. Set RS-485 Parameters You can set the access control device's RS-485 parameters including the baud rate, data bit, the stop bit, parity type, flow control type, communication mode, work mode, and connection mode.
  • Page 130: Door/Elevator Control

    DS-K3B530X Series Swing Barrier User Manual 3. Select an access control device in the device list and click Wiegand to enter the Wiegand Settings page. 4. Set the switch to on to enable the Wiegand function for the device. 5. Select the Wiegand channel No. and the communication mode from the drop-down list.
  • Page 131: Control Door Status

    DS-K3B530X Series Swing Barrier User Manual 8.8.1 Control Door Status You can control the status for the door(s), including unlock door, locking door, remaining the door unlock, remaining the door locked, remain all unlocked, etc. Before You Start Add person and assign access authorization to designed person, and person will have the access ●...
  • Page 132: Check Real-Time Access Records

    DS-K3B530X Series Swing Barrier User Manual All doors in the group will be closed and locked. No person can access the doors even if he/she has the authorized credentials, except the super users. Capture Capture a picture manually. Note The Capture button is available when the device supports capture function. The picture is saved in the PC running the client.
  • Page 133 DS-K3B530X Series Swing Barrier User Manual 2. Optional: Select an access point group from the drop-down list in the upper-right corner to show the real time access records of the selected group. 3. Optional: Check the event type and event status.
  • Page 134: Appendix A. Dip Switch

    DS-K3B530X Series Swing Barrier User Manual Appendix A. DIP Switch A.1 DIP Switch Description The DIP switch is on the access control board. No.1 and No 2 is from the low bit to the high bit. Figure A-1 DIP Switch When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off.
  • Page 135: Appendix B. Button Configuration Description

    DS-K3B530X Series Swing Barrier User Manual Appendix B. Button Configuration Description Refer to the table below for device configuration via button on the main lane control board. Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Study Mode 1-Exit Study Mode/...
  • Page 136 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions 5-Entrance on inductive mode; exit under control 6-Entrance on inductive mode; exit prohibited 7-Both sides prohibited 8-Entrance prohibited; exit under control 9-Entrance prohibited; exit on inductive mode 10-Entrance under control;...
  • Page 137 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions 18-Entrance remaining open; exit remaining open 19-Entrance remaining open; exit on free mode 20-Entrance remaining open; exit prohibited 21-Entrance on free mode; exit under control 22-Entrance on free mode;...
  • Page 138 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Barrier Opening Speed 1-1, 2-2, …10-10 Note By default, 5 will be displayed on the display screen. Barrier Closing Speed 1-1, 2-2, …10-10 Note By default, 5 will be displayed on the display screen.
  • Page 139 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Note By default, 0 will be displayed on the display screen. Intrusion Duration 0-0s, 1-1s, 2-2s,..., 20- Note By default, 0 will be displayed on the display screen.
  • Page 140 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions 2-Single Lane Note By default, 1 will be displayed on the display screen. Motor Rotation 1-Clockwise Unable to change 2-​ A nticlockwise Note By default, 1 will be displayed on the display screen.
  • Page 141 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Fingerprint Unmatched 1-Disable Unable to change via button 2-Enable Note By default, 1 will be displayed on the display screen. Climbing over Barrier 1-Disable 2-Enable...
  • Page 142 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Forced Passing 1-Disable Unable to change via button 2-Enable Note By default, 1 will be displayed on the display screen. Tailgating Alarm 1-Disable 2-Enable Note...
  • Page 143 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Expired Credential 1-Disable Unable to change via button 2-Enable Note By default, 1 will be displayed on the display screen. Overstaying Alarm 1-Disable 2-Enable Note...
  • Page 144 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions Note By default, 8 will be displayed on the display screen. Motor Inspection 1-Disable 2-Enable on Main Lane 3-Enable on Sub Lane Note By default, 1 will be displayed on the display screen.
  • Page 145 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions 4-4,6-6,8-8, Unable to change via button Note By default, 4 will be displayed on the display screen. Application Mode 1-Wind-proof 2-Indoor By default, 1 will be displayed on the display screen.
  • Page 146 DS-K3B530X Series Swing Barrier User Manual Level-1 Configuration Description Level-1 Configuration Notes No. and Functions By default, 1 will be displayed on the display screen. 1-Disabled 2-Enabled By default, 2 will be displayed on the display screen. Barrier Height 1-700...
  • Page 147: Appendix C. Event And Alarm Type

    DS-K3B530X Series Swing Barrier User Manual Appendix C. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None...
  • Page 148: Appendix D. Table Of Audio Index Related Content

    DS-K3B530X Series Swing Barrier User Manual Appendix D. Table of Audio Index Related Content Note If the device is not equipped with access control board, the loudspeaker shall be connected to ● the main extended interface board. If the device is equipped with access control board, the loudspeaker shall be connected to the ●...
  • Page 149: Appendix E. Error Code Description

    DS-K3B530X Series Swing Barrier User Manual Appendix E. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason...
  • Page 150: Appendix F. Communication Matrix And Device Command

    Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure F-2 Device Command...
  • Page 151 UD30992B...

This manual is also suitable for:

Ds-k3b530xDs-k3b530lx

Table of Contents