Mitsubishi Electric Mr.Slim PLA-A BA6 Series Installation Manual page 9

Split-system heat pump
Table of Contents

Advertisement

Available languages

Available languages

6. Electrical work
Service menu
Test run
Input maintenance info.
Function setting
Check
Self check
Main menu:
Cursor
F1
F2
F3
F4
Fig. 6-6
Function setting
Grp.
Ref. address
Mode 1
Mode 2
Mode 3
Mode 4
Request:
Cursor
Cursor
F1
F2
F3
F4
Fig. 6-8
Function setting
Ref. address
Grp.
Sending data
F1
F2
F3
F4
Fig. 6-10
CHECK
ON/OFF
TEMP
FAN
AUTO STOP
MODE
VANE
AUTO START
CHECK
LOUVER
h
TEST RUN
min
SET
RESET
CLOCK
Fig. 6-11
Function setting
Ref. address
Unit No.
Grp./1/2/3/4/All
Monitor:
Cursor
Address
F1
F2
F3
F4
Fig. 6-7
Function setting
Unit # 1
Ref. address
Mode 7
Mode 8
Mode 9
Mode10
Request:
Cursor
Cursor
F1
F2
F3
F4
Fig. 6-9
CHECK
CHECK
CHECK
CHECK
6.3. Function settings
6.3.1. Function setting on the unit (Selecting the unit functions)
1) For wired remote controller
1 (Fig. 6-6)
• Select "Service" from the Main menu, and press the [SELECT] button.
• Select "Function settings" with the [F1] or [F2] button, and press the [SELECT]
button.
2 (Fig. 6-7)
• Set the indoor unit refrigerant addresses and unit numbers with the [F1]
through [F4] buttons, and then press the [SELECT] button to confi rm the cur-
rent setting.
<Checking the Indoor unit No.>
When the [SELECT] button is pressed, the target indoor unit will start fan opera-
tion. If the unit is common or when running all units, all indoor units for the se-
lected refrigerant address will start fan operation.
3 (Fig. 6-8)
• When data collection from the indoor units is completed, the current settings
appears highlighted. Non-highlighted items indicate that no function settings
are made. Screen appearance varies depending on the "Unit No." setting.
4 (Fig. 6-9)
• Use the [F1] or [F2] button to move the cursor to select the mode number, and
change the setting number with the [F3] or [F4] button.
5 (Fig. 6-10)
• When the settings are completed, press the [SELECT] button to send the set-
ting data from the remote controller to the indoor units.
• When the transmission is successfully completed, the screen will return to the
Function setting screen.
2) For IR wireless remote controller (Fig. 6-11)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
Going to the function select mode
CHECK
Press the
button
twice continuously.
(Start this operation from the status of IR wireless remote controller display turned
off.)
is lighted and "00" blinks.
CHECK
Press the
temp button
once to set "50". Direct the IR wireless remote control-
ler toward the receiver of the indoor unit and press the
Setting the unit number
Press the
temp buttons
and
wireless remote controller toward the receiver of the indoor unit and press the
button
.
Selecting a mode
Enter 04 to change the power voltage setting using the
. Direct the IR wireless remote controller toward the receiver of the indoor unit
and press the
h
button
.
Current setting number:
1 = 1 beep (one second)
2 = 2 beeps (one second each)
3 = 3 beeps (one second each)
Selecting the setting number
Use the
temp buttons
and
V). Direct the IR wireless remote controller toward the sensor of the indoor unit and
h
press the
button
.
To select multiple functions continuously
Repeat steps
and
to change multiple function settings continuously.
Complete function selection
Direct the IR wireless remote controller toward the sensor of the indoor unit and
press the
button
.
Note: Whenever changes are made to the function settings after installation
or maintenance, be sure to record the changes with a mark in the "Setting"
column of the Function table.
6.3.2. Function setting on the remote controller
Refer to the appropriate operation manual included with each remote controller.
h
button
.
to set the unit number "00". Direct the IR
temp buttons
to change the power voltage setting to 01 (240
min
and