Edwards A506-36-880 Instruction Manual
Edwards A506-36-880 Instruction Manual

Edwards A506-36-880 Instruction Manual

Acoustic enclosure for xds scroll pumps and rotary vane pumps

Advertisement

Quick Links

Acoustic Enclosure for XDS Scroll Pumps and Rotary Vane Pumps
Description
XDS Acoustic Enclosure
XDS Acoustic Enclosure
RV/EM Acoustic Enclosure
RV/EM Acoustic Enclosure
Instruction Manual
Electrical Supply
200-240 V 50/60 Hz
110-120 V 50/60 Hz
200-240 V 50/60 Hz
110-120 V 50/60 Hz
A506-36-880
Issue A Original
Item Number
A506-36-903
A506-36-906
A506-35-903
A506-35-906

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A506-36-880 and is the answer not in the manual?

Questions and answers

Summary of Contents for Edwards A506-36-880

  • Page 1 A506-36-880 Issue A Original Instruction Manual Acoustic Enclosure for XDS Scroll Pumps and Rotary Vane Pumps Description Electrical Supply Item Number XDS Acoustic Enclosure 200-240 V 50/60 Hz A506-36-903 XDS Acoustic Enclosure 110-120 V 50/60 Hz A506-36-906 RV/EM Acoustic Enclosure...
  • Page 2 Declaration of Conformity Edwards Limited, Crawley Business Quarter, Manor Royal, Crawley, West Sussex, RH10 9LW, UK declare under our sole responsibility, as manufacturer and person within the EU authorised to assemble the technical file, that the product(s) EM/RV Enclosure High volts...
  • Page 3: Table Of Contents

    Fitting end cover ......................6 Removing front panel to view sight glass ................9 Removing panel to gain access to filler cap ................. 9 © Edwards Limited 2012. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 4 Tables Table Page Pump noise levels ......................2 Associated publications Publication title Publication number Vacuum pump and vacuum system safety P400-40-100 Page ii © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 5: Introduction

    Scope and definitions The Acoustic Enclosure is designed to be used in an industrial or laboratory environment. All Edwards XDS and nXDS scroll pumps will fit the XDS Acoustic Enclosure and all RV and EM pumps up to E2M28 will fit the RV/EM Acoustic Enclosure.
  • Page 6: Technical Data

    Two fans are fitted. Fan 1 starts up when the power is on. Fan 2 is controlled by a thermal switch set to operate when the internal temperature exceeds 35 ± 5°C. Environmental conditions: Altitude 2000 m Ambient temperature 30°C Page 2 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 7: Installation

     Ensure that all equipment is safe and in a suitable condition to be installed in the enclosure.  For safety issues, refer to Edwards Vacuum Pump and Vacuum System Safety Publication P400-40-100 or  contact Edwards if in doubt.
  • Page 8: Installing The Xds Acoustic Enclosure

    Figure 3 - Locating left hand panel on side of pump Figure 4 - Fitting second cover to right hand side of pump Page 4 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 9: Installing Rv Em Acoustic Enclosure

    The various elements of the Enclosure are designed to slot together without additional fixings. Figure 5 - Attaching inlet and exhaust fittings © Edwards Limited 2012. All rights reserved. Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 10: Locating First Panel On Left Hand Side Of Pump

    Figure 6 - Locating first panel on left hand side of pump Figure 7 - Fitting second cover to right hand side of pump Figure 8 - Fitting end cover Page 6 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 11 Fit Second Cover on right hand side of pump - refer to Figure  Fit end cover - refer to Figure  © Edwards Limited 2012. All rights reserved. Page 7 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 12: Operation

    It is recommended that the user should use appropriate techniques to monitor the pump temperature and initiate protective measures in fault-intolerant applications. Page 8 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 13: Maintenance

    Figure  CAUTION With the pump enclosed by the Acoustic Enclosure, regular checks of the pump oil level should be made. © Edwards Limited 2012. All rights reserved. Page 9 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 14: Servicing

    The outside surface can be cleaned with a damp cloth and mild detergent. Do not allow water near the electrical components. Page 10 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 15: Disposal

    Dispose of any used equipment safely in accordance with all local and national safety and environmental requirements. Ensure the battery is disposed of safely in accordance with all local and national safety and environmental requirements. © Edwards Limited 2012. All rights reserved. Page 11 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 16 A506-36-880 Issue A This page has been intentionally left blank. Page 12 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 17 This page has been intentionally left blank.
  • Page 18 This page has been intentionally left blank.
  • Page 19 Download the latest documents from www.edwardsvacuum.com/HSForms/, follow the procedure in HS1, fill in the electronic HS2 form, print it, sign it, and return the signed copy to Edwards. Note: If we do not receive a completed HS2 form, we will not accept the return of the...
  • Page 20 edwardsvacuum.com...

This manual is also suitable for:

A506-36-903A506-36-906A506-35-903A506-35-906