Sloan OPTIMA 195 Installation Instructions Manual

Sloan OPTIMA 195 Installation Instructions Manual

System sensor activated concealed with true mechanical override flushometers

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS FOR OPTIMA
CONCEALED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS
MODEL 152
Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3)
years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or
refund the purchase price of any product which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive remedy under this warranty. Products must be returned
to Sloan Valve Company, at customer's cost. No claims will be allowed for labor, transportation or other costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company's
products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY
CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
ROUGH-IN
MODEL 152
‡ When installing in a handicap stall:
Position of the sensor box can be raised or lowered 1" (25 mm) if in conflict with
handicap grab bars. Per the ADA guidelines (section 604.9.4), it is required that
grab bars be split or shifted to the wide side of stall.
SYSTEM SENSOR ACTIVATED
®
MODEL 195

LIMITED WARRANTY

MODEL 195
L DIM. 2¾"
+
(70 mm)
WALL
THICKNESS
19"
(482 mm)
Concealed Closet Flushometers
1-1/2" Rear Spud
• Model 152 ES-S TMO SBX
Concealed Urinal Flushometers
3/4" Rear Spud
• Model 195 ES-S TMO SBX
4¾"
2¾"
(121 mm)
(70 mm)
SENSOR LOCATION & POSITIONING IS
CRITICAL!
Failure to properly position the electrical boxes
to the plumbing rough-in will result in improper
installation and impair product performance.
All tradesmen (plumbers, electricians, tile
setters, etc.) involved with the installation of
this product must coordinate their work to
assure proper product installation.
Code No. 0816877
Rev. 2 (02/20)
¾"
(DN 20 mm)
IPS
SUPPLY
1½"
(38 mm)
13½"
3½"
(343 mm)
(89 mm)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTIMA 195 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sloan OPTIMA 195

  • Page 1 Unless otherwise noted, Sloan Valve Company warrants this product, manufactured and sold for commercial or industrial uses, to be free from defects in material and workmanship for a period of three (3) years (one (1) year for special finishes, SF faucets, PWT electronics and 30 days for PWT software) from date of first purchase. During this period, Sloan Valve Company will, at its option, repair, replace, or refund the purchase price of any product which fails to conform with this warranty under normal use and service.
  • Page 2 DO NOT supply power to transformer until installation of flushometer is complete. Note: A maximum of ten (10) flushometer units can operate from one (1) Sloan EL-154 Transformer, Class 2, UL Listed, 50 VA (min.) at 24 VAC, plate mounted.
  • Page 3 Nylon Slip Before inserting the scored ends into the Elbow, apply several drops of Tube Gasket Loctite (supplied by Sloan) to the scored ends of the tubes. This sealant Rubber helps prevent separation under high-pressure conditions. DO NOT use any Gasket other pipe sealant or lubricant on this connection.
  • Page 4 Do Not Overtighten. NOTE Max. adjustment of Sloan Adjustable Tailpiece is ½” (13 mm) IN or OUT from the standard 4¾” (121 mm) (C L of Valve to C L of Control Stop). If roughing-in measurement exceeds 5¼” (133 mm), consult factory for longer tailpiece.
  • Page 5 7 - ELECTRICAL HOOK-UP Wiring Diagram for One Flush Valve Be certain power is OFF to prevent damage to electrical components. Connect sensor to transformer and solenoid coil EXACTLY as shown. Connect 24 volt source lead to terminal labeled “24 VAC IN” of sensor. SENSOR Connect solenoid lead to terminal labeled “TO VALVE”...
  • Page 6 Open control stop COUNTERCLOCKWISE one (1) FULL turn from the closed position. !!! IMPORTANT !!! All Sloan Flushometers are engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper...
  • Page 7 When further assistance is required, B. Low consumption unit is installed on water saver or conventional fixture. please contact Sloan Technical Support at: Replace diaphragm component parts of valve with kit that corresponds to 1-888-SLOAN-14 (1-888-756-2614) appropriate flush volume of fixture.
  • Page 8 The information contained in this document is subject to change without notice. SLOAN • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: +1.800.982.5839 or +1.847.671-4300 • Fax: +1.800-447.8329 or +1.847.671.4380 • www.sloan.com © 2020 SLOAN Code No.0816877– Rev. 2 (02/20)

This manual is also suitable for:

Optima 152