Relocation And Maintenance; Pumping Down - Mitsubishi Electric MSZ-AP50VGK Installation Manual

Hide thumbs Also See for MSZ-AP50VGK:
Table of Contents

Advertisement

5. CONNECTION SETUP OF THE Wi-Fi INTERFACE (VGK type only)
7KLV SURGXFW LV HTXLSSHG ZLWK WKH :L)L ,QWHUIDFH DV VWDQGDUG
5HIHU WR WKH 6(783 48,&. 5()(5(1&( *8,'( DQG 23(5$7,1* ,16758&7,216 SURYLGHG ZLWK WKH LQGRRU XQLW IRU FRQQHFWLRQ ZLWK WKH URXWHU

6. RELOCATION AND MAINTENANCE

6-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY
Removal procedure
 2SHQ WKH IURQW SDQHO
 5HPRYH WKH IURQW SDQHO
 5HPRYH WKH  VFUHZV ZKLFK ¿[ WKH SDQHO /
 5HPRYH WKH SDQHO /
 5HPRYH WKH  VFUHZV ZKLFK ¿[ WKH SDQHO 5
 5HPRYH WKH SDQHO 5
 5HPRYH WKH SDQHO 8
 5HPRYH WKH SDQHO )
Installation procedure
 ,QVWDOO WKH SDQHO DVVHPEO\ IROORZLQJ WKH UHPRYDO
SURFHGXUH LQ UHYHUVH
 %H VXUH WR SUHVV WKH SRVLWLRQV DV LQGLFDWHG E\ WKH
DUURZV LQ RUGHU WR DWWDFK WKH DVVHPEO\ FRPSOHWHO\
WR WKH XQLW
6-2. REMOVING THE INDOOR UNIT
5HPRYH WKH ERWWRP RI WKH LQGRRU XQLW IURP WKH LQVWDO-
ODWLRQ SODWH
5HOHDVH ERWK OHIW DQG ULJKW ERWWRP SDUW RI LQGRRU XQLW
DQG SXOO LW GRZQZDUG DQG IRUZDUG DV VKRZQ LQ WKH
¿JXUH RQ WKH ULJKW
5
5
2
1
3
8
6
4
7
5
3

6-3. PUMPING DOWN

:KHQ UHORFDWLQJ RU GLVSRVLQJ RI WKH DLU FRQGLWLRQHU SXPS GRZQ WKH V\VWHP IROORZLQJ WKH
SURFHGXUH EHORZ VR WKDW QR UHIULJHUDQW LV UHOHDVHG LQWR WKH DWPRVSKHUH
 &RQQHFW WKH JDXJH PDQLIROG YDOYH WR WKH VHUYLFH SRUW RI WKH VWRS YDOYH RQ WKH JDV SLSH
VLGH RI WKH RXWGRRU XQLW
 )XOO\ FORVH WKH VWRS YDOYH RQ WKH OLTXLG SLSH VLGH RI WKH RXWGRRU XQLW
 &ORVH WKH VWRS YDOYH RQ WKH JDV SLSH VLGH RI WKH RXWGRRU XQLW DOPRVW FRPSOHWHO\ VR WKDW LW
FDQ EH HDVLO\ FORVHG IXOO\ ZKHQ WKH SUHVVXUH JDXJH VKRZV  03D >*DXJH@  NJIFPð 
 6WDUW WKH HPHUJHQF\ &22/ RSHUDWLRQ
7R VWDUW WKH HPHUJHQF\ RSHUDWLRQ LQ &22/ PRGH GLVFRQQHFW WKH SRZHU VXSSO\ SOXJ DQG
RU WXUQ RII WKH EUHDNHU $IWHU  VHFRQGV FRQQHFW WKH SRZHU VXSSO\ SOXJ DQGRU WXUQ RQ
WKH EUHDNHU DQG WKHQ SUHVV WKH (2 6: RQFH 7KH HPHUJHQF\ &22/ RSHUDWLRQ FDQ
EH SHUIRUPHG FRQWLQXRXVO\ IRU XS WR  PLQXWHV
 )XOO\ FORVH WKH VWRS YDOYH RQ WKH JDV SLSH VLGH RI WKH RXWGRRU XQLW ZKHQ WKH SUHVVXUH
JDXJH VKRZV  WR  03D >*DXJH@ DSSUR[  WR  NJIFPð 
 6WRS WKH HPHUJHQF\ &22/ RSHUDWLRQ
3UHVV WKH (2 6: VHYHUDO WLPHV XQWLO DOO /(' ODPSV WXUQ RII 5HIHU WR RSHUDWLQJ LQVWUXF-
WLRQV IRU GHWDLOV
WARNING
When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes. The compressor may burst if air etc. get into it.

Advertisement

Table of Contents
loading

Table of Contents