Assembling and Adjusting arms
3-1
if necessary, insert the plastic
socket from inside the C-piece.
Attaching VESA plate to monitor
3-2
Attaching arm to post
4-a
Position O-ring at desired height. Thread Wishbone over post.
Attaching arm to toolbar
4-b
Remove the monitor from the arm when
fixing or adjusting.
Ensure both plastic sockets are
screwed in sufficiently to allow
fixing of the movement joint.
Non quick release
movement joint
O-Ring
Using a 6 mm allen key, tighten
both plastic sockets equally to
secure the movement joint
centrally within the C-piece. The
joint is secure when it rotates
with a small amount of resistance.
Quick release
movement joint
Ensure the screw or pig tail is
tightened sufficiently after fixing or
adjustment.
Ensure sockets are equally tightened and the movement joint is
securely held in the plastic sockets.
Screws for screen are NOT provided,
please contact your monitor provider.