Signaling Precedence (Tos): (Default, 0 Routing)
Selection from 0 (Routing), 1 (Priority), 2 (Immediate), 3 (Flash), 4 (Flash Override) and 5
(CRITIC/ECP)
Voice Precedence (Tos): Default, 0 Routing)
Selection from 0 (Routing), 1 (Priority), 2 (Immediate), 3 (Flash), 4 (Flash Override) and 5
(CRITIC/ECP)
RFC2833 Payload Type: (Default, 101)
DTMF RFC2833 Payload Type, ranging from 96 ~ 127
Room Number:
The key of Room Keeper feature that the master and client devices will look for each other by
using the same room number.
SIP Mode: (Default, Master)
BYOD Master will always act as master SIP mode.
Log Server: (Default, blank is disable)
Please fill in the IP address of the AEi IMM Server. The device then reports status to IMM server,
such as firmware version, IP address of the device, cordless handset status and etc. Also it
accepts commands from it, such as firmware updating, restart, reset to factory default and etc.
Replace Sharp: (Default, Enable)
The "#" in the sending string will be sent as %23% if it is enabled.
The "#" in the sending string will be send as # if it is disabled
MWI To Tag: (Default, Disable)
This is for Broadworks compatibility. Set to enable while interoperating with Broadworks.
Caller ID: (Default, Disable)
To display caller ID on the display, select Enable; otherwise select Disable.
Register P-Asserted-Identity: (Default, Disable)
Enable to support P-Asserted-Identity in SIP registration.
Session Timer: (Default, 0 is disable)
To enable session timer, input the value in seconds ranging from 1 ~ 9999. The minimum session is
120 seconds; any number less than 120 will be set to 120.
Hot Line: (Default, blank is disable)
Input an extension number to enable hot line feature. This feature is also known as Ring Down.
Debug Mode: (Default, blank is disable)
Input the IP address of a log server (UDP; port: 514) to send the log of the phone system.