Calibration Unit for Testers
Installation, Operation and Maintenance
Figure 1. Desco
07010

Description

The Desco
Calibration Unit is designed to verify
07010
whether a tester is operating within specifications.
This product can be used as one of the tools to fulfill
the ANSI/ESD S20.20 paragraph 6.1.3.2 "Compliance
Verification Plan." The
passive device and requires no power source. The
Calibration Unit is manufactured with industry accepted
test ranges for both wrist straps and foot grounders.
The wrist strap pass range is set at 750K - 10M, while
the foot ground test range is set at 750K - 100M. The
Desco Calibration Unit is calibrated to NIST traceable
standards.
The Desco
Calibration Unit is to be used with the
07010
following items:
Item
Description
19240

Wrist Strap Tester

19250
19252
Combo Wrist Strap / Footwear Tester with
Stand
19253
Combo Wrist Strap / Footwear Tester with
Foot Plate
19350
Wrist Strap Touch Tester, 220VAC
19351
TB-2039 Page 1 of 4
July 2012
TECHNICAL BULLETIN TB-2039

Calibration Unit

Calibration Unit is a
07010
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website:

Packaging

1 Calibration Unit
2 Test Leads with Banana Plug Terminals
1 Certificate of Calibration

Operation

WRIST STRAP TESTER
1. Plug one of the included test leads into the black banana
jack labeled "E" on the Calibration Unit. Connect the
opposite end of the test lead into the yellow banana jack
located on the
19240
Wrist Strap Tester.
Figure 2. Connecting the test lead from banana jack "E"
on the Calibration Unit to the banana jack on the Wrist
Strap Tester
2. Connect the second test lead to the red 675K banana jack
labeled "A" on the Calibration Unit. Touch the opposite
end of the test lead to test plate on the Wrist Strap Tester
and press down to activate the test. Be sure not to touch
the banana plug or test plate with your skin.
3. Observe the response from the Wrist Strap Tester. The
alarm should sound, and the LOW LED should illuminate
red.
4. Repeat the procedure for test points B (825K), C (8.5M)
and D (11.5M). The expected test results can be found in
the following table.
Test
Resistance
Test Output
Point
Value
675K
FAIL LOW
A
B
825K
PASS
8.5M
PASS
C
D
11.5M
FAIL HIGH
Made in the
United States of America
Desco.com
© 2012 DESCO INDUSTRIES, INC.
Employee Owned

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 07010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Desco 07010

  • Page 1 PASS 11.5M FAIL HIGH DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-2039 Page 1 of 4 July 2012 © 2012 DESCO INDUSTRIES, INC.
  • Page 2 D (120M). The expected test results can be found in the following table. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-2039 Page 2 of 4 ©...
  • Page 3 D (11.5M). The expected test results can be found in the following table. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: Desco.com TB-2039 Page 3 of 4 ©...
  • Page 4 Limit of Liability In no event will Desco or any seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product. Before using, users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith.