Fig.62
Heating curve graph
9.4

Reading out measured values

Fig.63
INFO menu access
F1 F1 F1
F2 F3 F4
Tab.29
Read-only parameter list (not editable)
Setting
Description
(read only)
AM001
DHW (Domestic Hot Water) mode enabled (0: Disabled, 1: Enabled)
AM010
Pump speed (0 ÷ 100%)
AM011
Service required (0: Disabled, 1: Enabled)
AM012
Status of appliance
AM014
Sub Status of appliance
AM015
Pump operation (0: Disabled, 1: Enabled)
58
800 Combi 2
Tout: temperature detected by the outside sensor (° C)
SP_CH: Heating flow temperature setpoint (°C)
Proceed as described below to access the info menu:
Press the F3 key;
The
symbol flashes on the display;
Press the F4 key to access the INFO menu;
Turn the
knob to view the settings;
Press the F1 key to exit.
9 Settings
Value
0/1
%
0/1
List of statuses
List of sub-sta­
tuses
0/1

Advertisement