Technical Precautions - Aiphone 83873900 0602 E Installation Manual

Health care communication system for nursing homes & health care facilities
Table of Contents

Advertisement

5. OPERATIONS on NHX-50M
Call tone & light annunciation
At NHX-50M Master station
• Receiving
• Line-off trouble
• While talking
At NH-1SA/A, NH-1SA, NH-2SA/A or NH-2SA Bedside Sub station
• Placing
• While talking
• When master calls in
At NHR-4A Room Corridor lamp (white/red)
• When Sub placed a call Routine call
At NHR-3A-4 Zone light
• When Sub placed
At NHR-3TS sub station (w/corridor lamp) in Common area or Hallway
Placing
At NHR-SP Duty station
• When Master received Routine call
While Master talking
Calling from NHX-50M
When NHX-50M has called a bedside Sub station, no light turns on on the corridor lamp, zone light and sub station
except TALK LED lit green on the sub station.
6
6
6
6

TECHNICAL PRECAUTIONS

Temperatures
NHX-80X and NHX-50M are rated to operate at
temperatures 10˚C~49˚C(50˚F~120˚F).
Duty Station Operation
At NHR-SP, sub station call-in is annunciated by
tone & LED, which are the same as on
NHX-50M.
• The TONE-OFF button silences tone, but CALL
LED remains lit. When the NHX-50M begins
communication, both tone and LED are
deactivated.
• 90 seconds after the call tone is muted, it will ring
again. Press TONE-OFF button, and it will no
longer ring (tone will resume when another sub
calls).
Type of calling
Routine call
Bathroom call (urgent)
Cord-out trouble call
Bedside sub from Trunk
Duty station from NHX-80X Faster buzzer, intermittent
Routine call
Bathroom call (urgent)
Cord-out trouble call
Bathroom call (urgent)
Cord-out trouble call
While talking
Routine call
Urgent call
Cord-out trouble call
Bathroom call (urgent)
Staff call (urgent)
Urgent call
Cord-out trouble call
Call tone
Single chime, every 6 sec.
Single chime, every 2 sec.
Single chime, every 0.5 sec.
Slow buzzer, intermittent
Call tone (as above)
Pre-tone
Single chime, every 6 sec.
Single chime, every 2 sec.
Single chime, every 0.5 sec.
Call Holding
Every Routine call is held electronically at bedside
sub station, and will be automatically connected
when handset is lifted or TALK button is pressed at
the NHX-50M. To reset the call, press CANCEL
button on the Sub station. When a Bathroom call &
Cord-out trouble call is activated, the LED will
remain on even after the NHX-50M has answered.
The call must be reset at the calling site.
– 30 –
(*) Sound & LED time is approximate.
Light
Blinking, every 2 sec.
Double blinking, every 1.8 sec.
Blinking fast, every 0.4 sec.
Lit 0.2 sec., every 2 sec.
No light
Call-in LED steadily lit
CALL steadily lit
Not lit
CALL lit on Pullcord switch
CALL steadily lit.
CALL is off, and TALK is on.
TALK is on
White steadily lit
Red blinking
White blinking
Not lit
1 ~ 4 lamp turns on for any call from
Bedside sub or NHR-3TS.
Red blinking on NHR-3TS
White blinking on NHR-3TS
CALL blinking, every 2 sec.
CALL double blinking, every 1.8 sec.
CALL blinking fast,every 0.4 sec.
Not lit