Installation Location
The LP tank is installed inside the base cabinet, on the
tank scale (right side). The shape of the collar assembly
(the metal protective ring around the tank valve)
determines one of two directions in which the tank will
correctly hang on the tank scale (A).
Inspect the Tank
1) Confirm that the tank valve is fully closed. Close by
turning valve clockwise.
2) Confirm that the tank valve is the proper mating
type for the regulator (B).
3) Inspect the tank valve, including the internal rubber
seal for damage or debris (C). If damaged, return
tank to local retailer.
Install The Tank
1) Check that all burner control knobs are in the
off
position. Check by pushing in and turning
knobs clockwise.
2) Open base cabinet door.
3) Loosen hand nut and rotate tank lock up (D).
4) Lift tank into position on the tank scale (E).
5) Rotate the tank lock down. Tighten the hand nut.
6) Screw the regulator coupling onto the tank valve,
turning clockwise (F). Hand-tighten only. Using a
wrench could damage the regulator coupling and
could cause a leak. Proceed to "CHECKING FOR
GAS LEAKS."
A
B
C
D
E
F
9