Cooking Mode
G. Temperature Display
To select temperature display in ° C or ° F for temperature in the Setup Menu:
1. Select "temperature in °C,"
2. Con rm by pressing the Smart Key.
3. Select "yes" for ° C and "no" for ° F
4. Con rm the selection with the Smart Key.
5. The temperature display is set as speci ed.
H. Network Address
NOTES:
The Network Address is factory set to "1."
Select a di erent network address for each appliance.
The network address is required for the use of PC Control, PC-HACCP and the Convotherm by
Cleveland Service System.
To set the Network Address from the Setup Menu:
1. Use the Selector Dial to select "Network Address"
2. Con rm by pressing the Smart Key.
3. The display shows the network address currently set.
4. Use the Selector Dial to select the desired network address (1 - 99)
5. Con rm by pressing the Smart Key.
I. Language
To select a language from the Setup Menu.
1. Choose, select "Language"
2. Con rm by pressing the Smart Key.
3. The languages available appear in the display.
4. Use the Selector Dial to select the desired language
5. Con rm by pressing the Smart Key.

Factory Default Settings

Oven Temperature
212° F
302° F
338° F
275° F
Table 10-1
with the Selector Dial
Core Temperature
Cooking Time
158° F
158° F
158° F
158° F
.
25 min
70 min
30 min
5 min