#<password>* t<ch>=<test-period>
Sets the test period in minutes, for the given channel. The period value can be between
0 and 65535, setting 0 will disable test reports. The device will restart within 30 seconds.
#<password>* tc=<test-code>
#<password>* tc<ch>=<test-code>
Sets the test code globally, or by individual channels. Please, take care to program a
valid Contact-ID code. The device will restart within 30 seconds.
#<password>* o<n>=<on/off>
Can be used to control the on-board outputs of the commnunicator. Value of<n> can
be 1 or 2. The corresponding I/O of the device should be programmed as an output,
and the operation of the output follows the preprogrammed scheme. The output can be
activated with the „on", or „1" values, and deactivated with „off" or „0".
#<password>* ox<n>=<on/off>
Can be used to control the outputs of the IO-84 module(s), connected to the
communicator. Value of<n> can be 1 to 8. The operation of the corresponding output of
the IO-84 will follow its preprogrammed scheme. The output can be activated with the
„on", or „1" values, and deactivated with „off" or „0". When no IO-84 module(s) are
connected to the communicator, the command will be acknowledged, but ignored.
#<password>* p<n>=< phone-nr>
The command can be used to set the telephone numbers, which can activate the gate-
control function. Value of <n> can be between 1 and 8. To use the gate-control function,
some of the outputs of the communicator (or a connected IO-84 module) must be
enabled and set to „gate-control" mode. In this mode, any calls received from the given
telephone numbers will activate the corresponding output.
– pl.: #1234* t4=10
– pl.: #1234* tc=1603
– pl.: #1234* tc5=1602
– pl.: #1234* o1=on
– pl.: #1234* o1=on
– pl.: #1234* p5=36301234567