Page 2
NOTICE The contents of this booklet are subject to change without prior notice. No part of this booklet may be reproduced or transferred, in any form, for any purpose, without the permission of Noise Laboratory Co., Ltd. The contents of this booklet have been thoroughly checked. However, if a doubtful point, an error in writing or a missing is found, please contact us.
1. IMPORTANT SAFETY PRECAUTIONS The following instructions are very important for safe handling of the Coupling Adapter CA-805B. They must be kept strictly to prevent users of the Unit from receiving harm or damage through using the Unit. Read them carefully before use.
2. APPLICATION FORM FOR INSTRUCTION MANUAL To: Noise Laboratory Co., Ltd. We place an order for an instruction manual. CA-805B MODEL: Serial No.: Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No.: Cut off this page "APPLICATION FORM FOR INSTRUCTION MANUAL"...
3. CONTENTS 1. IMPORTANT SAFETY PRECAUTIONS ................1 2. APPLICATION FORM FOR INSTRUCTION MANUAL ............3 3. CONTENTS ........................5 4. INTRODUCTION ......................6 5. BASIC PRECAUTIONS FOR SAFETY IN USE OF THIS UNIT ..........8 5-1. Hazard symbols and its meaning ................... 8 5-2.
3. Direct noise injection into the signal line enabling effective checking of the level of noise immunity. 4. The cable to be tested of up to 26mm in diameter can be put through the CA-805B.
5. BASIC PRECAUTIONS FOR SAFETY IN USE OF THIS UNIT 5-1. Hazard symbols and its meaning It expresses a WARNING. WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. It expresses a CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Page 11
5.BASIC PRECAUTIONS FOR SAFETY IN USE OF THIS UNIT During test, high level of electromagnetic radiation may be generated depending on the type or nature of the EUT and thus causing interference with nearby electronic equipment and radio communication equipment. In such case, the user may have to take measures such as a faraday cage, shielded room, shielded cable and so on.
7. MAIN UNIT AND ACCESSORIES Quantity A : CA-805B main unit ··················································································1 B : Coaxial cable (1.5m) ···············································································2 Connector type:NMHV(P) - NMHV(P) ,Accessory cord: 02-00025A MODEL C : Instruction manual (this booklet) ······························································1...
① Connect the ground plane to the earth terminal of the test room with using an appropriate cable to ground it. ② Put the impulse noise tester, the CA-805B body, and EUT properly on the ground plane. In case EUT is floor-top type, put the insulation pallet first and put EUT on the insulation pallet.
Page 15
For details, refer to“8-2. Avoiding misuse of HV coaxial connector”. ⑤ Undo the buckle and put the cable to be tested through the CA-805B body. Care should be taken to position the cable with a minimum variation in distance to the surface of the internal conductor ※...
Noise Laboratory has been renewing the type of coaxial connectors in accordance with making output pulse voltage of Impulse Noise Simulators higher. The high voltage coaxial connector “NMHV” used for this product (CA-805B) is the exclusive –use connector for Noiseken’s products which was developed for using for impulse noise simulators which output pulse voltage exceeds 3kV.
9. WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. 1. Scope The following terms shall apply only to products made by the Company. 2.
Page 19
9.WARRANTY Limited warranty Noise Laboratory Co., Ltd.(hereafter referred to as the Company) warrants its products to be free from defects in materials and workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
10. MAINTENANCE 1. When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. 2. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. 3.