Cooling System
Radiator Coolant Level/Changing Coolant
This procedure is required only if the cooling system has been drained
for maintenance and/or repair. If the overflow bottle has run dry, the
level in the radiator should also be inspected.
CAUTION! Escaping steam can cause burns. Never remove the pressure cap
while the engine is warm or hot. Always allow the engine to cool before
removing the pressure cap.
1. Remove the hood. See page
31.
2. Slowly remove the radiator
pressure cap.
3. View the coolant level
through the opening.
4. Use a funnel and slowly add
coolant as needed.
5. Before reinstalling the pres-
sure cap, bleed the system of
trapped air. Remove the
engine access panel behind
the seats and use a flat-blade
screwdriver to turn the bleed
screw slightly, allowing the
air to escape. Slowly add
additional coolant to the
radiator until air no longer
escapes and only coolant
flows from the bleed hole,
then tighten the bleed screw.
6. Reinstall the pressure cap.
Tip: Use of a non-standard pressure
cap will not allow the recovery
system to function properly.
Your POLARIS dealer can
provide the correct replacement
part.
MAINTENANCE
Pressure
Overflow
Cap
Bottle
Bleed Screw
99