MANUAL ADVANCE RECHARGE CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, recharge flow rates,
and other controller functions. Always make the initial
checks first, and perform the manually initiated elec-
tronic diagnostics.
NOTE: The display must show a steady time (not
flashing). If an error code shows, first press
the SELECT button to enter the diagnostic
display.
1. Press the RECHARGE button and hold in for 3
seconds. "RECHARGE", "Serv" and "Fill" begin to
flash in the display as the softener enters the fill
cycle of regeneration.
2. When valve reaches "Fill" position, remove the
brinewell cover and, using a flashlight, observe fill
water entering the tank.
3. If water does not enter the tank, look for an
obstructed nozzle, venturi, fill flow plug, brine tub-
ing, or brine valve riser pipe.
4. After observing fill, press the RECHARGE button to
move the softener into brining. A slow flow of
water to the drain will begin. Verify brine draw from
the brine tank by shining a flashlight into the
brinewell and observing a noticeable drop in the
liquid level.
5. If the softener does not draw brine:
= nozzle and/or venturi dirty
= nozzle and venturi not seated properly on gasket
= restricted drain (check drain fitting and hose)
= ineffective nozzle and venturi seal
= other inner valve problem (rotor seal, rotor &
disc, wave washer, etc.)
WIRING SCHEMATIC
120V AC
60 Hz
Troubleshooting
Pwr.
In
Power
Supply
24V DC
Tank
Light
OUT
Turbine
Sensor
GND
+5
Cam
NOTE: If water system pressure is low, an elevated
drain hose may cause back pressure, stopping
brine draw.
6. Again press RECHARGE to move the softener into
backwash. Look for a fast flow of water from the
drain hose.
7. An obstructed flow indicates a plugged top distribu-
tor, backwash flow plug or drain hose.
8. Press RECHARGE to move the softener into fast
rinse. Again look for a fast drain flow. Allow the
softener to rinse for a few minutes to flush out any
brine that may remain in the resin tank from the
brining cycle test.
9. To return the softener to service, press RECHARGE
once more.
Back of Electronic
Controller (PWA)
Tank
Position/
Light
Turbine
Motor
grn
org
C
23
Position Markers
(valve in service)
Motor
Status
Light
Valve
Motor
Position
NO
Switch
NC
FIG. 49