Sanosil Q-Jet CT20
Operating Manual
SANOSIL AG • CH-8634 Hombrechtikon • Switzerland
E-mail: service@sanosil.com
www.sanosil.com
Operating Manual Q-Jet CT20
© Sanosil
1/32

Advertisement

Table of Contents
loading

Summary of Contents for Sanosil Q-Jet CT20

  • Page 1 Sanosil Q-Jet CT20 Operating Manual SANOSIL AG • CH-8634 Hombrechtikon • Switzerland E-mail: service@sanosil.com www.sanosil.com Operating Manual Q-Jet CT20 © Sanosil 1/32...
  • Page 2 Operating Manual Q-Jet CT20 © Sanosil 2/32...
  • Page 3: Table Of Contents

    4.3 Creating room profiles ................................15 4.4 Loading and activating a saved room profile ........................17 4.5 Protocol ......................................18 5. Possible usage profiles for the Q-Jet CT20 ..........................19 6. Carrying out aerosol disinfection ..............................20 6.1 Room preparation ..................................20 6.2.
  • Page 4: Use Of Symbols

    Make sure that this manual is always available to the users of the device. 2.1 Intended use The device is a nebuliser for indoor applications using exclusively Sanosil disinfectants with a maximum hydro- gen peroxide content of 7.5%. Its purpose is to transform the disinfecting liquid used into minute particles and to nebulise them in a room, which then results in uniform disinfection of all uncovered surfaces in the room (3D disinfection).
  • Page 5: Improper Use

    Prevent aerosols containing peroxide from escaping into parts of the room with unprotected persons during and for some time after disinfection. Once the fogging process using the Sanosil Q-Jet has been completed, the air will be full of fogged Sanosil •...
  • Page 6 Caution: Electric shock! Do not connect the device to the power supply when parts of it are still wet. • Only use the power cable supplied by Sanosil AG. • No liquids must be allowed to enter the device. If this nevertheless occurs, disconnect the device from the •...
  • Page 7: Authorised Personnel

    The product is used despite obvious safety defects or identifiable damage. • The product has been subjected to mechanical shocks or dropped. • Accessories are used that are not included in the scope of delivery or expressly approved by Sanosil Ltd. • Operating Manual Q-Jet CT20 © Sanosil...
  • Page 8: Ct20: Technology

    4 cycles of a configurable length as well as 3 customisable intermediate pauses. The device is operated using a touchscreen and features a logging function. This makes it possible to save each disinfection process and export it via a USB stick. Operating Manual Q-Jet CT20 © Sanosil 8/32...
  • Page 9: Technical Device Information

    2-5 m (min.-max. power) Z: 850 mm For room sizes 6 - 600 m 3.3 Overview Handle Moisture meter Touchscreen Main switch Optical warning signal/status display Mist nozzle Turbine opening Ventilation openings Chassis Operating Manual Q-Jet CT20 © Sanosil 9/32...
  • Page 10: User Manual

    Wait until the General Settings screen appears • Select "General Settings" • The "General settings" menu opens • "Select language" allows you to select the • menu language "Date/time set" allows you to set the • date and time Operating Manual Q-Jet CT20 © Sanosil 10/32...
  • Page 11: Disinfection Mode

    Auto mode is ideal for straightforward and uncomplicated maintenance disinfection, e.g. in hotel rooms, gyms, restaurants and laboratories, etc. Press "Run" to treat a new room or to load a saved • room profile. Press "Quick Action" to treat a new room • Operating Manual Q-Jet CT20 © Sanosil 11/32...
  • Page 12 3 customisable intermediate pauses. This enables the best possible disinfection results, but also requires a certain understanding of aerosol mechanics and how the dosage, cycle and pause length interact depending on the room to be treated. Otherwise, unwanted condensation may form. Operating Manual Q-Jet CT20 © Sanosil 12/32...
  • Page 13 Press "Quick Action" to select an operating mode: • Select "Expert" • Define the room size in m and press "Next" at the • bottom right Select the desired number of disinfection cycles • Operating Manual Q-Jet CT20 © Sanosil 13/32...
  • Page 14 Then go to "Next" at the bottom right • Check all the specifications. Make sure that there • is enough liquid in the tank for the desired pro- gram. Otherwise, a corresponding warning field appears Start the cycle • Operating Manual Q-Jet CT20 © Sanosil 14/32...
  • Page 15: Creating Room Profiles

    Select "Room Settings" • Enter the password to get access. • Password:= "agent007" "Set room" allows you to create the room profile • "Delete Room" allows you to delete previously • saved room profiles Operating Manual Q-Jet CT20 © Sanosil 15/32...
  • Page 16 The room is then saved • After programming a room profile, the profile can be activated and started immediately by pressing "OK". Alter- natively, you can use "Back" to create and save additional room profiles. Operating Manual Q-Jet CT20 © Sanosil 16/32...
  • Page 17: Loading And Activating A Saved Room Profile

    Check all the specifications. Make sure that there • is enough liquid in the tank for the desired pro- gram. Otherwise, a corresponding warning field appears Start the cycle • Operating Manual Q-Jet CT20 © Sanosil 17/32...
  • Page 18: Protocol

    Create a folder and name it "DT" • Insert the USB stick and wait until the data is auto- • matically loaded onto it. (This may take some time). The data can then be used as Excel files Operating Manual Q-Jet CT20 © Sanosil 18/32...
  • Page 19: Possible Usage Profiles For The Q-Jet Ct20

    Instead, a forced ventilation/air exchange system is used to remove the hydrogen peroxide residues still remaining in the room. Advantages: Time required: 3-5 hours (depending on room size and air exchange rate), Sanosil Q-Jet and the room can be used again sooner. Disadvantages: Requires a powerful ventilation system with a separate supply and extract air system and a dedicated control system for each room.
  • Page 20: Carrying Out Aerosol Disinfection

    Make sure that fog does not trigger a false alarm • in your fire alarm system If necessary, cover individual detectors in the • room to be disinfected. Important: never switch off the entire fire alarm system Operating Manual Q-Jet CT20 © Sanosil 20/32...
  • Page 21: Device Preparation

    80% during fogging 6.2. Device preparation 6.2.1 Filling the device with disinfectant Disconnect the device from the mains. Put on gloves • and safety goggles Open the rear flap on the device • Operating Manual Q-Jet CT20 © Sanosil 21/32...
  • Page 22 This is irritating to exposed/unprotected skin or eyes. Wear protective equipment and avoid direct skin or eye contact with the liquid. Wipe up any drops or spilled Sanosil disinfectant immediately and wash the cloth or similar mate- rial used for this purpose well with water afterwards.
  • Page 23: Positioning The Device

    Place the warning door hanger and the information • sign with information about the current program and the expected end of the program in a clearly visible position on the door Operating Manual Q-Jet CT20 © Sanosil 23/32...
  • Page 24: After Disinfection

    P3) and gloves must be worn. As soon as the level of nebulised hydrogen perox- • ide in the air has decreased below 1 ppm, the room can be used again without any restrictions Operating Manual Q-Jet CT20 © Sanosil 24/32...
  • Page 25: Disinfectant Dosages

    8 ml/m 4400 ml >Max. tank capacity 8 ml/m 4800 ml >Max. tank capacity * the pause length depends on the room's ability to absorb (airborne) moisture. 30 minutes is usually a good value. Operating Manual Q-Jet CT20 © Sanosil 25/32...
  • Page 26 Room Quantity according to the Afnor T72-281 (2014) Consumption according to the Afnor T72-281 (2014) size standard, with Sanosil S015 for: bacteria, yeasts, standard, with Sanosil S015 for: bacteria, yeasts, moulds (28ml/m ) pause length 30 minutes moulds, spores (33 ml/m...
  • Page 27: Maintaining And Servicing The Device

    Used air filters may contain acid residues or hydrogen peroxide. Wear gloves and safety goggles for protection when changing the air filter. Dispose of used air fil- ters in a tightly sealed plastic bag. Operating Manual Q-Jet CT20 © Sanosil 27/32...
  • Page 28: Cleaning The Nozzle

    Also avoid wetting the equipment surfaces through contact with contami- nated gloves on the handles. Should liquid Sanosil disinfectant nevertheless get onto a surface of the device, immediately wipe it several times with a damp cloth.
  • Page 29: Troubleshooting

    Pull out the mains plug, call a ser- Pipe breakage or leakage in the vice technician Wear gloves/eye Liquid leaks from the device fluid circuit protection. Absorb leaked liquid and wipe with a wet cloth Operating Manual Q-Jet CT20 © Sanosil 29/32...
  • Page 30: Appendix

    9. Appendix 9.1 Declaration of Conformity Operating Manual Q-Jet CT20 © Sanosil 30/32...
  • Page 31: Warranty Conditions

    In particular, a disinfection liquid based on H / Ag produced by Sanosil AG is approved for use in this machine. It is the customer's responsibility to understand and follow the operating instructions in this manual and the specifications before starting operation.
  • Page 32: Disposal And Decommissioning

    Send the complaint form with the additional information and pictures and videos (if helpful) to "service@sanosil.com". 2. Sanosil AG will review the complaint with the manufacturer and decide whether the device must be re- turned to Switzerland or whether the device can be repaired locally by shipping spare parts via the Sa- nosil representative or its authorised repair centre.