Use of Sanosil Q-Jet in buildings for aerosol disinfection SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 2
Nosocominal Infections Nosocomial infections are among the most dreaded risks in modern medicine. Not least due to the prevalence of antibiotic-resistant germs. SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 3
Gap in effectiveness Manual cleaning and disinfection reach only 80 – 90% of potentially contami- nated surfaces. A risky gap in effectiveness remains! SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 4
Perfect 3D Hygiene An additional aerosol disinfection closes this effectiveness gap and achieves perfect 3D hygiene! SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 5
Aerosol Disinfection in 8 Easy Steps: How should one carry out a perfect aerosol disinfection? SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 6
1. Empty Room Make sure that the room to be treated is empty and does not need to be used for several hours! SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 7
2. Pre-Disinfection Clean the room thoroughly and disinfect all contact points and critical surfaces manually by wiping them down. SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 8
3. Prepare Room Close windows, doors, hatches etc., switch off air conditioning and ventilation. SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 9
4. Prepare Q-Jet Device Position the machine. Observe the prescribed safety distance (3 – 6 m, depending on the spray setting) to walls, ceiling and equipment. 20 - 22°C 40% rH SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 10
5. Aerosol Disinfection Action Nebulise the necessary amount of Sanosil S015. Make sure that 80% rH is not exceeded to avoid condensation. SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 11
6. Wait for reaction time Allow the fog to work for at least 2 hours (prefer-ably overnight). Do not enter the room during this time. SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 12
7. Prepare for Room Re-use Make sure the hydrogen peroxide level is < 1ppm before the room is used again. Otherwise, ventilate the room thoroughly. Level: < 1 ppm SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 13
8. Be safe again The room can be used again with perfect 3D hygiene! SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...
Page 14
BEST WITH: Sanosil Q-Jet and Sanosil S015 SANOSIL AG CH-8634 HOMBRECHTIKON, SWITZERLAND WWW.SANOSIL.COM SERVICE@SANOSIL.COM...