Return the product to SPM Instrument AB for examination. Sensor marking. For configuring the Airius sensor, only certified mobile devices are allowed to be used in Ex-hazardous areas. The batteries are classified as dangerous goods, when transported.
The letters ‘xy’ denote measurement performance (e.g. frequency bandwidth) and ‘Szz’ denote variations of op- erating software. AIR01-Ex is a member of the Airius family of wireless sensors. The Airius sensor is compatible with both Condmaster.NET, the application providing easy access to measurement data through a user-friendly interface, and the analysis and diagnostic software Condmaster Ruby.
Bandwidth, Resolution Temperature measurement: Part numbers Range –40 °C to +85 °C (–40 °F to +185 °F) AIR01-01-EX Airius Ex sensor, 2/4/8 g, 16 bits, Resolution 0.1 °C 10-1000 Hz, 800/1600 lines Accuracy +/– 2 °C...
4.1 Screw installation Installation must only be performed by competent Drill a screw hole where the sensor should be personnel. There are two methods for installing Airius Ex placed. sensors, either by screw installation or glue installation. Drill a counterbore with 30 mm diameter on the Position the sensor in such a way that it can optimally machine.
4.2 Glue installation Drill a counterbore with 30 mm diameter on the machine where the sensor should be placed. Screw the sensor onto the installation foot. Tighten- ing torque: 7 Nm. Apply glue (Loctite 326) and activator (Loctite 7649) to the installation foot. Check that the markings of the sensor align with the intended measurement directions.
20 s timeout or connection lost battery reverts to the software installed during factory production. Not configured 5.2 Clear settings via the SPM Connect app Clear settings continue to use the latest software while all settings are cleared. For more information, see chapter Button...
5.3 Setting up Airius with SPM Connect 1. Download the SPM Connect app via App Store or Google Play. 2. Press and hold the button on the Airius sensor until it lights blue. 3. Open the SPM Connect app. 4. Swipe down to search for a sensor. Choose a sensor in the list (A).
9. Choose Online under Instrument, choose settings as desired and select OK. 10. Go to the Online tab, select the Airius sensor and direction (z, x or y) under Address. Select OK. 11. Go to the Settings tab, name the assignment and edit the settings as desired.
11. Enter a name for the measuring assignment. 12. Choose a sensor under Measuring device. 13. To edit measuring interval, operational hours or measuring range for the Airius sensor, select Edit device settings. 14. Select the axes (z, x, y) to be measured.
3. Connect the plug and insert the new battery. Battery assembly, lid and screws may be replaced. All other repair measures may only be performed by SPM Warning: Use only SPM battery. Instrument AB. To clean the external surfaces of the 4.
Page 17
This product must be disposed as electronic waste and is marked with a crossed-out wheeled bin symbol in order to prevent it being discarded with household waste. When the life cycle of the product is over You can return it to Your local SPM representative for correct treatment, or dispose it together with your other electronic waste.
Need help?