Electrical Connection; Control Board Dipswitch Setting - Rinnai Infinity 16 external Operation And Installation Manual

Continuous flow and temperature control instantaneous gas water heater
Table of Contents

Advertisement

2.4.4 ELECTRICAL CONNECTION

Connect the appliance to a 220-240V ±10% / 50-60Hz power supply. Do not use
water or gas lines to ground the system.
The electric safety is guaranteed only when the appliance is properly grounded
and the grounding system has been realized following all the safety prescriptions
provided for by law.
Make sure that the electric system is suitable for the maximum power
consumption and is provided with a circuit breaker with overvoltage category III.

2.4.5 CONTROL BOARD DIPSWITCH SETTING

Improper setting of the switches will cause the appliance to operate incorrectly
The switches of the control board are set to without sideways flue diverter (SW1 and SW3:OFF)
as default setting.
IMPORTANT
When a sideways flue diverter is fitted the installer must set switches SW1 and SW3 to ON (right
position).
Factory default
DipSW
SW1 (OFF)
SW2 (OFF)
SW3 (OFF)
SW4 (OFF)
ON
Ground
3-prong plug
※The illustration above is an example
of grounding.
Sideways flue diverter
DipSW
SW1 (ON)
SW2 (OFF)
SW3 (ON)
SW4 (OFF)
ON
Ground
2-prong plug
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents