Introduction
Read this instruction manual before using the product in order to achieve maximum performance.
After reading it, keep the manual always at hand for future reference.
The following symbols alert you to important messages. Be sure to read these
messages carefully
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, could result in product damage as well as property damage.
Safety Information for X4
This product is not intended for use as explosion-proof product. Do not use this product in hazardous location and/or potentially explosion
WARNING
atmosphere.
You must verify that the X4 Series are operating correctly in terms of functionality and performance before the start and the operation of the X4.
CAUTION
We recommend that you take substantial safety measures to avoid any damage in the event of a problem occurring.
SEUIC never warrant the function or performance of the X4 Series if it is used in a manner that differs from the X4 Series specifications
contained in this instruction manual of if the X4 Series are modified by yourself.
NOTICE
When the X4 Series is used in combination with other instruments, functions and performance maybe degraded, depending on operating
conditions and the surrounding environment.
Safety Precautions on LED Product
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
WARNING
Do not stare into the beam.
Do not disassemble this product.
Precautions on Proper Use+
Do not use a voltage other than that described in the specifications with the X4 Series. Doing so may cause damage to the unit.
Be sure to turn off the power to devices attached to the X4 Series when you plug in or unplug the cables. Failure to do so may cause damage
to the X4 Series.
Do not disassemble or modify the X4 Series. Doing so may cause damage to the unit.
Place cables as far away as possible from high-voltage lines and power lines. Otherwise, electrical noise can be generated that may cause a
NOTICE
product failure or malfunction.
The X4 Series is a precision instrument. Do not impact or drop the instrument. Pay particular attention when transporting or installing the unit.
Do not allow water, oil, dust, or other foreign substances to stick to the scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substance from the scanner. (Do not use a cloth dipped in alcohol or other cleaning agent.)
Do not turn off the power of the X4 Series while accessing files. The internal data may be corrupted.
CE,FCC and RoHS Certificate
This product complies with the following CE,FCC and RoHS and has been certified by CE,FCC and RoHS.

Advertisement

loading
Need help?

Need help?

Do you have a question about the X4-1EF and is the answer not in the manual?

Questions and answers

Summary of Contents for Seuic X4-1EF

  • Page 1 We recommend that you take substantial safety measures to avoid any damage in the event of a problem occurring.  SEUIC never warrant the function or performance of the X4 Series if it is used in a manner that differs from the X4 Series specifications ...
  • Page 2: Package Contents

    Name Description Package Contents (1) Scanner Section that reads codes Package (2) RS232/IO port Port for connecting the Model Name Qty. Appearance RS232 Cable content USB/ Ethernet Port for connecting the USB cable or (3) port Cable Reader unit Power LED: It turns on when the X4 is connected to the external power supply.
  • Page 3 Connecting the Serial port and control cable and wiring 1. Align the protrusion in the cable connector with the notch in the control port. Serial port and I/O cable 2. Tighten the connector screw by turning it clockwise. 3. Connect the wires according to usage. (1)NPN wiring...
  • Page 4 (2)PNP wiring (3)Output wiring (signal tower light) Be sure to turn power off before attempting to connect or disconnect the control cable. Insert the connector straight so that it is not tilted and then tighten it securely. Under-tightening can lead NOTICE to a loose connector due to vibrations, resulting in poor contact.
  • Page 5 Connecting the Ethernet cable or USB cable 1. Align the protrusion in the cable connector with the notch in the Ethernet(USB) port and connect the cable to the main unit. 2. Tighten the connector screw by turning it clockwise.
  • Page 6 ETH or USB cable Mounting Methods 1. Secure the X4 unit with screws. Field of View and Installation Distance ( Mounting screws are included in the package) Distance Distance ( mm) (mm) 50 - 83 2mil 50-230 3.3mil 50-125 3.3mil 45-400 5mil 50-230...
  • Page 7: Specifications

    Specifications Model X4-1EF Sensor CMOS Image Sensor with global shutter Receiver 1.3M,1280 x 1080 Number of pixels Light source High-intensity red LED and blue LED Light emitter Aimer Laser dual-point positioning aimer Class II Focus adjustment Automatic Code128,GS1 128,Code39,Code93,codabar,2of5 (Industrial 2of5),EAN/UPC...
  • Page 8 Dimensions...
  • Page 9 Product Quick Configuration Codes Interface Settings TCP-Server TCP-Client RS-232 RS-485 USB COM USB HID...
  • Page 10 Technical Support You can download technical documents useful for product introduction and operation. 2023 SEUIC Company. All Rights Received. SEUIC Technologies Co., Ltd. Company address: NO.15 Xinghuo Road, Nanjing New High Technology Industry Development Zone, 210061, Nanjing City, Jiangsu Province, China.