13.15.1.7 Setting Position Judgment
According to installation position when there is only one activity area detected, the horizontal airflow direction
louver position is fixed according to chart below:
Target area
A
B
C
Louver position refer to horizontal airflow direction control.
When 2 activity areas have been detected, according to Human Activity Level, the timing of horizontal airflow
direction louver steps at the targeted activity areas is judged.
Operation mode
Cooling
When 3 activity areas have been detected, according to Human Activity Level the timing of horizontal airflow
louver steps at the targeted activity areas is judged.
Operation mode
Cooling
 When 3 activity areas have same activity level, the horizontal airflow direction louver will swing left and right.
13.15.1.8 Setting Temperature and Fan Speed Shift
 Cooling Dual Sensor
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.
Horizontal airflow direction louver position
Left installation
Center installation
3
1
5
Activity level difference
1 level
2 levels
Activity level
Hi
Me
Lo
Right installation
2
1
5
Louver stop time
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 30 seconds
Higher Activity level ≈ 60 seconds
Lower Activity level ≈ 8 seconds
Louver stop time
≈ 45 seconds
≈ 30 seconds
≈ 20 seconds
66
2
1
4

Advertisement