9 Manufacturer's information
9 Manufacturer's information
9.1 Delivery
● Check that all parts are present and check for any damage
immediately upon receipt.
The product's performance is tested at the factory. The scope
of delivery is apparent from the dispatch documents and the
design from the order number.
9.2 Transport
1. Only transport the product by suitable means. Do not drop.
Handle carefully.
2. After the installation dispose of transport packaging ma-
terial according to relevant local or national disposal regu-
lations / environmental protection laws.
9.3 Storage
1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their spare
parts.
GEMÜ 3240
10 Installation in piping
10.1 Installation and safety information
Risk of lightning strike!
▶ If there is an elevated risk of the device
Use of the product as a stepladder
▶ The housings are not designed to be used as a stepladder
for climbing in the plant. They can be damaged if used in
this way and their function impaired. If the housing is
damaged, water, dirt and combustible material can accu-
mulate in the housing interior. This can cause a short-cir-
cuit. Furthermore, the deposits can cause the device to
overheat and may result in an explosion.
▶ All interconnected components must be intrinsically safe.
The operator is responsible for ensuring that the entire
system (the entire circuit) is intrinsically safe.
▶ Handle the unprotected diaphragm with extreme care, as
it is very easily damaged.
▶ For use in steam pipes, provide a cooling zone.
▶ During installation, avoid high mechanical stresses on the
pressure connection. This can result in the characteristic
shifting or in damage, particularly for very narrow pres-
sure ranges and for devices with a plastic pressure con-
nection.
▶ With hydraulic systems, orientate the device such that the
pressure connection is facing upwards. (Vent hole)
▶ If the device is to be installed with the pressure connec-
tion at the top, make sure that no liquid flows away along
the housing as this could result in moisture and dirt
blocking the gauge reference in the housing and, in turn,
to the equipment malfunctioning. Where necessary, re-
move dust and dirt from the edge of the electrical con-
nection's union.
12 / 28
DANGER
being damaged by lightning or over-
voltage, an effective lightning protec-
tion system must additionally be put in
place.
DANGER
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
NOTICE
www.gemu-group.com