Unpacking Machine; Preparing Machine For Cleaning Application - Tennant Nobles ASC-15 Operator's Manual

All surface cleaner
Table of Contents

Advertisement

Available languages

Available languages

UNPACKING MACHINE

Carefully check carton for signs of damage. Report
damages to carrier immediately.
Check Carton Contents to ensure carton is complete.
Contact distributor for missing items.
Carton Contents:
--
Machine
--
Black Vacuum Hose (#610683)
--
Gray Blower Hose (#1010410)
--
Two Piece Double Bend Wand (#1010457)
--
(14 in) Squeegee Tool Attachment (#609648)
--
(12 in ) Glass Squeegee Hand Tool (#609641)
--
(5 in) Gulper Tool (#609645)
--
Blower Nozzle (#609644)
--
Fill Hose (#609983)
--
Spray Gun, Spray Nozzle and Solution
Hose (#610845)
--
Floor Brush Attachment (#609650)
--
Telescoping Wand for Floor Brush (#610731)
--
3 Metering Tips (bagged separately) (#609757)
--
Injector Tube Cap (Installed on blue tube)
--
Grease Gun for Pump (#190022)
PREPARING MACHINE FOR CLEANING
APPLICATION
INSTALLING LIQUID CLEANING AGENT
For specific cleaning agent recommendations, contact
your Tennant representative.
ATTENTION: Use of unapproved or inappropriate
chemicals may cause damage to machine and
surfaces and could void your warranty
1. Remove cap from the blue injector tube. Do not
misplace cap (Figure 1). Use cap to prevent injector
tube from clogging when machine is not in use.
FIG. 1
ASC- -15 / ASC- -57 (10- -11)
Home
Find... Go To..
2. Select the desired metering tip (Tips supplied with
machine) and thread tip into blue injection tube on
machine (Figure 2).
Orange Tip = 2 oz per gallon (15ml / L)
for light cleaning
Red Tip = 4 oz per gallon (30ml / L)
for medium cleaning
Blue Tip = 6 oz per gallon (44ml / L)
for heavy cleaning.
FIG. 2
3. Place the cleaning agent container into the
accessory tools/cleaning formula compartment.
Remove cap from container and attach blue
injector tube cap. Push blue tube to bottom of
container (Figure 3).
FOR SAFETY: When using machine, follow
mixing, handling, and disposal instructions
provided on chemical container instructions.
FIG. 3
ATTENTION: Do not add cleaning chemicals to the
solution tank.
OPERATION
EN
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nobles asc-57

Table of Contents