The basal thermometer

The basal thermometer

Measuring your basal temperature

Take your temperature at the same time, as soon as you wake up and before you get out of bed. You should have slept for at least 4 hours before the measurement. If you have slept for less than 4 hours before the measurement, enter the amount of sleep you have had in the Ovy app or activate „Disrupted sleep". Do not eat anything before the measurement and avoid physical exertion.
You can make oral, rectal or vaginal measurements, but you should always take the measurements in the same place in a cycle. We recommend taking the measurement under your tongue with your mouth closed.
The thermometer should not be changed during the cycle. If you change the thermometer during the cycle, you must also note it as a disruption, just like a change to the place of measurement. For this cycle, a reliable evaluation is then no longer guaranteed.

Press the On/Off button to switch on the device. A short acoustic signal will announce that the thermometer is switched on. The thermometer will carry out a self-test for about 2 seconds. During the selftest all segments of the display will appear.
Then the reference reading 36,50°C appears. Then the measurement symbol "°C" flashes and "Lo" is shown on the display. The thermometer is now ready for use. Insert the tip of the sensor into one of the two heat pockets under your tongue, to the left or right of the root of your tongue. The measurement sensor must have good contact with tissue.

Close your mouth and breath calmly through your nose so that the air from your breathing does not influence the measurement. During the measurement, the current temperature is displayed continuously, and the "°C" symbol flashes on and off. The measurement is completed when a stable temperature has been reached. When this stage has been reached, an acoustic signal is heard, the "°C" symbol stops flashing and the temperature measured is displayed. We recommend a measuring time of 3 minutes. If the temperature stability is reached earlier, the acoustic signal sounds. Please always wait until the end of the measurement before you remove the thermometer from the place of measurement. The measured value is saved until the next measurement. The device switches off automatically approx. 10 minutes after the end of the measurement. You can also switch off the thermometer before this time by pressing the On/Off button.

Memory

The last measured value is automatically saved. To display this value, press the On/Off button for more than 2 seconds. The last measured value is then shown. Once the button is released, the reference value of 36,50°C and "Lo" are shown on the display. The thermometer is ready to take a measurement and the previously stored measured value is automatically replaced by the new measured value.

Replacing the battery

  1. Replace the battery when the battery status indicator appears on the display:
  2. Slide back the battery compartment cover to remove it.
  3. Pull the battery holder carefully out of the housing by approx. 1 cm.
  4. Use a non-metallic object to push the battery out of its holder.
  5. Insert a new battery (type LR41 1.5V) with the + symbol facing upwards.
  6. Push the battery holder back into the housing and reattach the battery compartment cover. Ensure that you do not damage or displace the seal.

Empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury. This battery contains: Pb, Hg.

Notes on handling batteries

  • If your skin or eyes come into contact with battery fluid, rinse the affected areas with water and seek medical assistance.
  • warningChoking hazard! Small children may swallow and choke on batteries or the battery compartment. Store batteries out of the reach of small children.
  • Observe the plus (+) and minus (-) polarity signs.
  • I f a battery has leaked, put on protective gloves and clean the battery compartment with a dry cloth.
  • Protect batteries from excessive heat.
  • warningRisk of explosion! Do not throw batteries into a fire.
  • Do not charge or short-circuit batteries.
  • If the device is not to be used for a relatively long period, take the batteries out of the battery compartment.
  • Use identical or equivalent battery types only.
  • Always replace all batteries at the same time.
  • Do not use rechargeable batteries.
  • Do not disassemble, open or crush the batteries.

Cleaning the device

Clean the basal thermometer before and after each use with a soft cloth and isopropyl alcohol diluted with water or cold soapy water. The device can be immersed in water or a disinfectant solution to clean it. The maximum immersion time is 30 minutes. Do not sterilise the device by boiling, with gas or with an autoclave.

Storage and disposal

Please store the thermometer in the original protective cover when it is not in use.
The accuracy of this thermometer has been carefully checked and it has been developed with a long service life in mind. If the device is used for commercial medical purposes, it must be regularly tested for accuracy by appropriate means. Precise instructions for checking accuracy may be requested from the service address.
For environmental reasons, do not dispose of the device in the household waste at the end of its service life. Dispose of the device at a suitable local collection or recycling point in your country. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.

Error messages

The measured temperature is below 32.00°C and is therefore outside the measurement range.
The measured temperature is above 42.99°C and is therefore outside the measurement range.
Electronic fault in the device. If this occurs repeatedly, please contact the Medel International customer service team.

Technical data

Model Fertyl
Type OT20
Measurement range 32.00°C - 42.99°C
Measurement accuracy ± 0.05°C between 35.00°C and 38.00°C at an ambient temperature of 18°C - 28°C outside of this measuring and temperature range ±0.1°C
Display Liquid crystal display (LCD) with 5 digits
Storage and transportation conditions Temperature -20°C - +55°C Rel. humidity 15% - 95% 700 - 1060 hPa ambient pressure
Operating conditions Temperature 5°C - +40°C Rel. humidity 15% - 95% 700 - 1060 hPa ambient pressure
Battery Button cell type LR41 1.5 V

The Ovy app is free for iOS and AndroidTM

The Ovy app enables you to record your entire cycle and keep an eye on it at any time on your smartphone. Ovy is designed for women who want to have children. The app is available to download for free in the Apple App Store and Google Play. The Ovy app is a certified Class 1 medical device.

How does Ovy work?

The Ovy app works out your cycle automatically, without pen and paper. This includes your period, ovulation and your fertile and non-fertile windows. To do this, take your temperature when you wake up in the morning and enter this value (to two decimal places) in the Ovy app. To make the prediction even more accurate, add other body signals each day. You should ideally start recording this on the first day of your period; i.e. the first day of your menstrual cycle. However, you can also start recording on any day in your cycle. It is important that you record when potential external temperature influences such as a fever, consumption of alcohol or a lack of sleep have occurred.
You can also enter your basal temperature, body signals and influencing factors at a later time, but the temperature measurement should have been taken on the relevant day. The Ovy app is based on a self-learning algorithm. This means that the more often you enter your basal temperature, the more accurately Ovy will be able to predict your fertile days and your next period.

Do you have any questions about the Ovy app?

The Ovy team is on hand to help in such cases and you are welcome to e-mail us at hello@ovyapp.com. The Ovy app has a contact function in your profile, which you can also use to send us your questions and feedback directly. The Ovy website and the information sections in the app already offer some answers and diverse background information about your cycle.
Website: www.ovyapp.com
Contact: hello@ovyapp.com
Facebook: Ovy
Instagram: @ovyapp Twitter: @ovyapp

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Medel Fertyl - Digital Thermometer Manual

Advertisement

Need help?

Need help?

Do you have a question about the Fertyl and is the answer not in the manual?

Questions and answers

Table of Contents