Dss/Blf; Table 1-4 Level Assignment Conditions For Dss/Blf - NEC NEAX 2400 IMX System Manual

Direct station selection (dss) console
Hide thumbs Also See for NEAX 2400 IMX:
Table of Contents

Advertisement

term
3.
Multiple D
s cannot use one DSS console.
4.
Circuit cards for the DSS are as follows:
PA-16ELCJ
PA-DAIG-A (DAI)
PA-DAIJ-A (DAI)
The previous conditions also apply when a Distributed Access Unit (DAU) is used between the PBX and the
DSS.

6. DSS/BLF

One DSS/BLF console requires 2 consecutive ports on an ELC/DAI card.
When a DSS console is used as a DSS/BLF, be sure to assign and wire the DSS/BLF to a specific LEN whose
level (LV) is an even number (LV = 0, 2, 4, 6). Since a DSS/BLF requires 2 consecutive ports to program the
DSS keys, the port following the designated port, to which the DSS/BLF is wired, must be reserved.
LEVEL NUMBER
2n
2n + 1
In
Table
1-4, "n" represents 0, 1, 2, 3.
Note:

Table 1-4 Level Assignment Conditions for DSS/BLF

A DSS console can be connected.
Must be reserved for the DSS console.
ND-70684 (E)
CONDITIONS
OVERVIEW
DSS/BLF
CHAPTER 1
Page 7
Revision 1.0

Advertisement

Table of Contents
loading

Table of Contents