Velocity VDOT-STB-RL Instruction Manual

Relay base

Advertisement

Quick Links

Instruction Manual
VDOT-STB-RL
Relay Base
Before Installation
Please read these instructions carefully and keep for future reference.
The information in this document is subject to change without notice. For updates please refer to our website.
Do not disassemble, repair, or modify the products. It may cause a fire or electric
shock.
Note: Follow the requirements for the installation of the products in accordance with the Specifications. Otherwise
it may cause damage to equipment.
Note: Do not install the product in any location where oil, dust, iron powder, chemicals, or hydrogen sulphide may
occur or affect the product. It may cause damage to equipment.
Section 1 – INTRODUCTION
VDOT-STB-RL is a detector base with relay output for use with Zeta Control Panel series, which is designed for
use with an addressable detector. When a detector is in alarm condition, the base receives a control signal from
the detector, which has the relay operate. The rating of contact is DC30V/1A.
Section 2 – TERMINALS
VDOT-STB-RL base is supplied with 2 terminals as standard, along with a relay output terminal block of C form
contact.
The terminals of VDOT-STB-RL base are configured as follows:
-Terminal 1 = SLC positive
-Terminal 6 = SLC negative
-Terminal 3 = No connection
- Relay terminal block with N/O, N/C, and COM
! CAUTION
1
ZETA ALARMS LIMITED
72-78 MORFA ROAD, SWANSEA, SA1 2EN
http://www.velocitydetection.com
GLT-299-7-9 Rev. 0
Mar 23, 2018

Advertisement

loading

Summary of Contents for Velocity VDOT-STB-RL

  • Page 1: Section 1 - Introduction

    Section 1 – INTRODUCTION VDOT-STB-RL is a detector base with relay output for use with Zeta Control Panel series, which is designed for use with an addressable detector. When a detector is in alarm condition, the base receives a control signal from the detector, which has the relay operate.
  • Page 2: Section 3 - Dimensions

    NO CONNECTION Figure 1: Position of terminals Section 3 – DIMENSIONS 22.5 (0.885) 105(4.133) mm(inch) Figure 2: Dimension of VDOT-STB-RL GLT-299-7-9 Rev. 0 Mar 23, 2018...
  • Page 3: Section 4 - Detector Models

    Section 4 – DETECTOR MODELS VDOT-STB-RL Base is available for use with the VDOT series detectors. It is important to use the correct detector for each application. The standard range of detectors available is as follows: Model Description Instruction Manual...
  • Page 4: Section 6 - Connections

    NFPA 72. In normal use, the VDOT-STB-RL base will be installed at ceiling level. Pass the field wiring through the cable hole in the center and from the rear of the base. Hold and affix the base to the ceiling or electrical box with screws via the base mounting holes.
  • Page 5: Section 7 - Maintenance

    Section 7 – MAINTENANCE Maintenance The VDOT-STB-RL is a high quality product engineered for reliability. In order to obtain optimum performance, periodic maintenance is required, at lease in accordance with NFPA 72 chapter 14 “Inspection, Testing and Maintenance”.
  • Page 6: Section 8 - Specifications

    3) Operate the detector in accordance with each detector's instruction manual as mentioned in Section 4. Check that the LED indicator on the detector illuminates. When the detector goes into an alarm status, confirm that the output relay of the product is in operation (close between N/O and COM, open between N/C and COM). Note: If the test cannot be carried out by operating the detector, remove the detector and short between terminal 3 and 6 to check the relay switches.
  • Page 7: Section 9 - Warranties

    FOR WARRANTY SERVICE, RETURN TO: ZETA ALARMS LIMITED 72-78 MORFA ROAD, SWANSEA, SA1 2EN http://www.zetaalarmsystems.com Section 9 – WARRANTIES 1.1 Zeta warrants to the customers that: (a) all products supplied hereunder will be of merchantable quality and will comply with any specification agreed between Zeta and customer.