Velocity VDOT-S6 Instruction Manual

Sounder base
Hide thumbs Also See for VDOT-S6:

Advertisement

Quick Links

Instruction Manual
VDOT-S6 Base
Sounder Base
Before Installation
Please read these instructions carefully and keep for future reference.
The information in this document is subject to change without notice. For updates please refer to our website.
Do not use the products outside the rated power supply voltage range specified in
the Specifications. It may cause a fire or damage to equipment.
Note: Follow the requirements for the installation of the products in accordance with the Specifications. Otherwise
it may cause malfunction.
Note: Do not install the product in any location where oil, dust, iron powder, chemicals, or hydrogen sulphide may
occur or affect the product. It may cause damage to equipment.
Section 1 – INTRODUCTION
VDOT-S6 Base is a detector base with sounder which is individually or collectively controlled by Velocity MMP
Control Panel series using addressable system and designed to be used with the model VDOT-PY, VDOT-PYH,
VDOT-DPH, and VDOT-H2 detector head.
The detector base has 4 sound patterns which are continuous, march, ANSI 3 temporal and 4 temporal patterns.
These patterns which are used in and around buildings can be selected by the control panel. Only ANSI 3
temporal pattern shall be used for UL Listed applications.
The sounder pressure level at 3 m (10 ft.) from the base is over 85 dB.
127 bases can be connected to a loop of the control panel.
The base is designed to be mounted to 3-1/2" octagonal, 4" octagonal or 4" square electrical box.
72-78 MORFA ROAD, SWANSEA, SA1 2EN
! CAUTION
1
ZETA ALARMS LIMITED
http://www.velocitydetection.com
GLT-299-7-10 Rev.0
Jun 12, 2018

Advertisement

Table of Contents
loading

Summary of Contents for Velocity VDOT-S6

  • Page 1: Section 1 - Introduction

    It may cause damage to equipment. Section 1 – INTRODUCTION VDOT-S6 Base is a detector base with sounder which is individually or collectively controlled by Velocity MMP Control Panel series using addressable system and designed to be used with the model VDOT-PY, VDOT-PYH, VDOT-DPH, and VDOT-H2 detector head.
  • Page 2: Section 2 - Terminals

    Section 2 – TERMINALS VDOT-S6 Base is supplied with 5 terminals as standard. The terminals of VDOT-S6 Base are configured as follows: Terminal Description SLC positive Not used SLC negative Aux. supply positive Aux. supply negative Figure 1: Position of terminals GLT-299-7-10 Rev.0...
  • Page 3: Section 3 - Dimensions

    Figure 2: Dimension of VDOT-S6 Base Section 4 – DETECTOR MODELS VDOT-S6 Base is available for use with the VDOT series detectors. It is important to use the correct detector for each application. The standard range of detectors available is as follows:...
  • Page 4: Section 5 - General Operation

    NFPA 72. In normal use, the VDOT-S6 Base will be installed at ceiling level or wall position. Please refer to specific detector instruction manual for details. Pass the field wiring through the cable opening in the center and from the rear of the base.
  • Page 5: Locking Screw

    Electrical box Base *Screws(M4) are not included in the package Figure 3: Installation to electrical box Locking Screw Turn the locking screw counterclockwise until the screw extends out about 4mm (3/16”) from the rim of the base. Figure 4: Position of locking screw GLT-299-7-10 Rev.0 Jun 12, 2018...
  • Page 6: Section 8 - Connections

    Section 8 – CONNECTIONS Splice connector or terminal block should be used. LOOP+ LOOP- LOOP+ LOOP- Approved VDOT-MiniIP Control VDOT-S6 VDOT-S6 Base Base Panel Series +24V AUX. PWR+ 24VG VDOT-PCE AUX. PWR- 24 VDC Power supply If the AUX. power supply circuit needs...
  • Page 7: Section 9 - Maintenance

    Section 9 – MAINTENANCE Maintenance The VDOT-S6 Base is a high quality product engineered for reliability. In order to obtain optimum performance, periodic maintenance is required, at least in accordance with NFPA 72 chapter 14 “Inspection, Testing and Maintenance”. Routine Inspection Ensure the detector head and the base are secure and undamaged.
  • Page 8: Section 10 - Specifications

    Section 10 – SPECIFICATIONS SLC Applied Voltage Rated Range 20VDC to 38VDC AUX. Supply Voltage Rated Range 16VDC to 33VDC SLC Current Consumption Standby 0.5mA Alarm 1.4mA AUX. Supply Current Consumption Standby 0.5mA Alarm 20mA SLC Line Impedance Up to 50ohms (See note 1) AUX.
  • Page 9: Section 11 - Warranties

    Section 11 – WARRANTIES 11.1. Zeta warrants to the customers that: all products supplied hereunder will be of merchantable quality and will comply with any specification agreed between Zeta and customer. it is not aware of any rights of any third party in the market which would or might render the sale of the products, or the use of any of the trade marks on or in products, or the use of any of the trade marks on or in relation to the products, unlawful.
  • Page 10 Turn the power switch ON. a) For one second, all LED’s are lit and the buzzer sounds. Connect the red alligator clip to the terminal 1 of VDOT-S6 Base and the black alligator clip to the terminal 6. Figure A.1: Connection between VDOT-AD2 and VDOT-S6 Base Press the [Search] Key a) Buzzer sounds, then the VDOT-AD2 starts transmitting to the base.
  • Page 11 [address] at the end of the second cycle. Type of device is assigned to the base as below. VDOT-S6 Base: Pressing any key at any time during the information collection cycle, forces the VDOT-AD2 to display the address, and await new address selection.