DROK Bidirectional Voltage Current Meter
https://www.droking.com
1
Product Introduction
DROK Bidirectional Voltage Current Meter (VAH9030H) is a new
type of voltage amp meter that can measure voltage, current,
charge-discharge capacity, time, power and other electric
parameters. It can also set parameters for over-voltage
protection, under-voltage protection, over-current protection,
over-charging capacity protection and over-time protection.
The non-contact Hall sensor is used to detect the current,
which is safe and convenient. Moreover, this meter adopts
color LCD to display data, which is a more comprehensive
and humanized design.
Parameters
Model
Current Measurement Range
Display Resolution
Internal power supply (10-90)V
Voltage Measurement Range
External power supply (0-90)V
Current Precision
Voltage Precision
Voltage
Display
Capacity
Resolution
Time
Measurement rate
OVP(Over-voltage protections)
OPP( Over-power protections )
LOP( undervoltage protection)
OCP( Over-current protections )
OAH( Over-charge protection )
OFT( Over-time protection )
1min~99hour59min
Size
Open holes(mm)
Sheet1 VAH9030H Parameters
Meter Panel
1
2
3
4
5
Number
Instructions
Voltage Value
1
2
Current Value
3
Volume Percent and Progress Bar
4
AH (blue),Power value (yellow)
5
WH (blue),Time (yellow)
6
Menus
7
Button
2
Power Expansion Board Wiring
Pictures below show the circuits in the discharging mode.
For charging, you just need to change the load to the charger
and there is no need for changing the circuit. If the current
enters and flows out from the front and back of the transformer,
the remaining battery capacity decreases, and conversely, the
remaining battery capacity increases.
Wiring of Internal Power Supply Wiring without Relay
Battery
-
+
VAH9030H
0-300A
0.1A
-
+
Load
Image 2 VAH9030H Power expansion board connection
±3%±5digits
±2%±5digits
a) Connect the "BAT" terminal with the power supply;
0.01V
b) Cross the wire which connecting the positive terminals of
0.01AH
the load and battery through the hole of the Hall sensor, then
0.01H(1min)
check whether the jumper cap is at J4;
5time/second
c) Plug the terminals of the wires connecting the positive and
0.01V~90V
negative of the battery into the "BAT" , and then power on.
0.01W~9.99KW
Note: To avoid reverse connection or wrong connection, wiring
0.01V~90V
should be done according to Image 2.
0.1~300A
0.01AH~9999AH
Wiring of External Power Supply without Relay
79×43×52(mm)
76.5*39.2(mm)
Battery
-
+
7
-
+
Load
Image 3 VAH9030H Power expansion board connection
6
a)Connect the "BAT" terminal with the power supply;
Image 1 Meter Panel
b)Cross the wire which connecting the positive terminals of
the load and battery through the hole of the Hall sensor,
then check whether the jumper cap is at J3;
c) Plug the terminals of the wires connecting the positive
and negative of the battery into the "BAT" , connect the
external power supply (12V-60V), and then power on.
Note: To avoid reverse connection or wrong connection,
wiring should be done according to Image 3.